Spectroscopy and Spectral Analysis, Volume. 41, Issue 9, 2748(2021)

Study on Near-Infrared Spectrum Acquisition Method of Non-Uniform Solid Particles

Hao-guang LI*, Yun-hua YU1; 2;, Yan PANG1;, and Xue-feng SHEN1; 2;
Author Affiliations
  • 1. College of Mechanical and Contral Engineering, Shandong Institute of Petrochemical and Chemical Technology, Dongying 257061, China
  • show less
    Figures & Tables(8)
    Structure diagram of self-made spectrum acquisition device(a): Diffuse reflection experimental device;(b): Diffuse transmission experimental device
    Top view of MircroNIR 1700 micro spectrometer
    • Table 1. Identification accuracy of case S1 (%)

      View table
      View in Article

      Table 1. Identification accuracy of case S1 (%)

      方法NBCKNNSVMBPANNBPR
      漫反射75.082.081.583.085.5
      漫透射80.085.690.691.195.0
    • Table 2. Identification accuracy of case S2 (%)

      View table
      View in Article

      Table 2. Identification accuracy of case S2 (%)

      方法NBCKNNSVMBPANNBPR
      漫反射74.081.582.583.585.5
      漫透射80.585.591.291.095.0
    • Table 3. Identification accuracy of case S3(%)

      View table
      View in Article

      Table 3. Identification accuracy of case S3(%)

      方法NBCKNNSVMBPANNBPR
      漫反射69.070.075.375.580.2
      漫透射81.085.090.890.595.0
    • Table 4. Identification accuracy of case S4(%)

      View table
      View in Article

      Table 4. Identification accuracy of case S4(%)

      方法NBCKNNSVMBPANNBPR
      漫反射65.070.373.575.680.6
      漫透射81.285.391.591.596.5
    • Table 5. Identification accuracy of different test sets with BPR method (%)

      View table
      View in Article

      Table 5. Identification accuracy of different test sets with BPR method (%)

      组合类型采集方式T2T3T4T5
      S1漫反射
      漫透射
      84.5
      96.5
      83.0
      96.0
      83.5
      95.5
      82.0
      94.0
      S2漫反射
      漫透射
      84.5
      96.7
      83.5
      95.5
      83.0
      95.0
      82.5
      94.5
      S3漫反射
      漫透射
      80.3
      95.5
      79.5
      95.5
      79.5
      94.0
      78.0
      93.0
      S4漫反射
      漫透射
      82.5
      95.5
      81.5
      95.3
      80.5
      95.3
      79.0
      95.0
    • Table 6. Identification accuracy of different test sets under diffuse transmission mode (%)

      View table
      View in Article

      Table 6. Identification accuracy of different test sets under diffuse transmission mode (%)

      方法T2T3T4T5
      BPR95.594.592.391.5
    Tools

    Get Citation

    Copy Citation Text

    Hao-guang LI, Yun-hua YU, Yan PANG, Xue-feng SHEN. Study on Near-Infrared Spectrum Acquisition Method of Non-Uniform Solid Particles[J]. Spectroscopy and Spectral Analysis, 2021, 41(9): 2748

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Jan. 20, 2021

    Accepted: --

    Published Online: Oct. 29, 2021