Laser & Optoelectronics Progress, Volume. 57, Issue 22, 221101(2020)
Preliminary Study on Determining the Sequence of Intersecting Lines Using Optical Coherence Tomography
[1] Poulin G. Establishing the sequence of strokes: the state of the art[J]. International Journal of Forensic Document Examiners, 2, 16-32(1996).
[2] Han W[M]. Theory and new technology of identification of seals and stamps identification about forensic science, 7-15(2018).
[3] Ellen D. The scientific examination of documents: methods and techniques[M]. 2nd ed. London: Taylor & Francis(1997).
[4] Feng C, Liu K M, Li J[J]. The research of sequence determination of seal and printed characters by measuring the stroke width Forensic Science and Technology, 2012, 35-38.
[5] Wang X G, Hao H G, Wang J S et al. Experimental study on the timing of printed text and laser printed handwriting using fuser transfer method[J]. Journal of Chinese People's Public Security University (Science and Technology), 17, 5-8(2011).
[6] Han W[J]. A study on identification of analyzing the sequence of handwriting and stamp by resistance measurement technology Journal of Criminal Investigation Police University of China, 2019, 97-102.
[7] Radley R W. Determination of sequence of ball point pen writing utilizing infrared luminescence techniques[J]. Journal of the Forensic Science Society, 22, 373-375(1982).
[8] Kim J, Kim M, An J et al. Determination of the sequence of intersecting lines using focused ion beam/scanning electron microscope[J]. Journal of Forensic Sciences, 61, 803-808(2016).
[9] Li B, Ouyang G L, Zhao P N. Preliminary study on determining the sequence of intersecting lines by fluorescence technique[J]. Journal of Forensic Sciences, 63, 577-582(2018).
[10] Jia Y W, Zou M L[M]. Inspection of Chinese criminal science and technology encyclopedia(2002).
[11] Cheng K C, Chao C H, Jeng B S et al. A new method of identifying writing sequence with the laser scanning confocal microscope[J]. Journal of Forensic Sciences, 43, 348-352(1998).
[12] Wei S, Liu S, Chen W N et al[J]. Sequencing of the crossed stamp impression and printed text by polarized microscope Chinese Journal of Forensic Sciences, 2018, 60-63.
[13] Kasas S, Khanmy-Vital A, Dietler G. Examination of line crossings by atomic force microscopy[J]. Forensic Science International, 119, 290-298(2001).
[14] Song Z Y, Bai X F[J]. Sequencing of cross strokes by three-dimensional stereomicroscope Chinese Journal of Forensic Sciences, 2018, 56-60.
[15] Fabiañska E, Kunicki M. Raman spectroscopy as a new technique for determining the sequence of intersecting lines[J]. Problems of Forensic Sciences, 53, 60-73(2003).
[16] Li B. An examination of the sequence of intersecting lines using microspectrophotometry[J]. Journal of Forensic Sciences, 61, 809-814(2016).
[17] Bojko K, Roux C, Reedy B J. An examination of the sequence of intersecting lines using attenuated total reflectance Fourier transform infrared spectral imaging[J]. Journal of Forensic Sciences, 53, 1458-1467(2008).
[18] Bao R, Zhang C X[J]. Research on the application of spectral imaging in sequencing writing and stamp impressions Chinese Journal of Forensic Sciences, 2008, 36-38.
[19] Kaur R, Saini K, Sood N C. Application of video spectral comparator (absorption spectra) for establishing the chronological order of intersecting printed strokes and writing pen strokes[J]. Science & Justice, 53, 212-219(2013).
[20] Huang D, Swanson E, Lin C et al. Optical coherence tomography[J]. Science, 254, 1178-1181(1991).
[23] Cense B, Chen T C, Park B H et al. In vivo birefringence and thickness measurements of the human retinal nerve fiber layer using polarization-sensitive optical coherence tomography[J]. Journal of Biomedical Optics, 9, 121-125(2004).
[24] Chen Z P, Zhao Y H, Srinivas S M et al. Optical Doppler tomography[J]. IEEE Journal of Selected Topics in Quantum Electronics, 5, 1134-1142(1999).
[27] Welzel J, Lankenau E, Birngruber R et al. Optical coherence tomography of the human skin[J]. Journal of the American Academy of Dermatology, 37, 958-963(1997).
[32] Wang Z G, Durand D B, Schoenberg M et al. Fluorescence guided optical coherence tomography for the diagnosis of early bladder cancer in a rat model[J]. Journal of Urology, 174, 2376-2381(2005).
[36] Choi W J, Min G H, Lee B H et al. Counterfeit detection using characterization of safety feature on banknote with full-field optical coherence tomography[J]. Journal of the Optical Society of Korea, 14, 316-320(2010).
[37] Meissner S, Breithaupt R, Koch E. Fingerprint fake detection by optical coherence tomography[J]. Proceedings of SPIE, 8571, 85713L(2013).
[39] Choi W J, Pi L Q, Min G et al. Qualitative investigation of fresh human scalp hair with full-field optical coherence tomography[J]. Journal of Biomedical Optics, 17, 036010(2012).
[40] Dubey S K, Anna T, Shakher C et al. Fingerprint detection using full-field swept-source optical coherence tomography[J]. Applied Physics Letters, 91, 181106(2007).
[41] Zhang N, Wang C M, Sun Z W et al. Characterization of automotive paint by optical coherence tomography[J]. Forensic Science International, 266, 239-244(2016).
[43] Chen J T, Chen W N. Research on the application of micro 3D stereo imaging technology in sequencing writing and stamp impressions[J]. Journal of Railway Police College, 26, 36-40(2016).
[44] Drexler W, Fujimoto J G. Optical coherence tomography[M]. Berlin: Springer(2008).
[45] Zhang Q Q. Spectral domain optical coherence tomography and the application in biomedicine[D]. Tianjin: Nankai University, 25(2012).
[46] Wang L. Research and implementation of wideband high resolution frequency synthesizer[D]. Chengdu: University of Electronic Science and Technology of China, 8(2017).
[47] Zhang N. Study of the endoscopic spectral-domain optical coherence tomography[D]. Beijing: Tsinghua University, 3(2014).
[48] Pan W B. Modeling and analysis of thermal bubble inkjet based on hybrid system theory[D]. Xi’an: Xidian University, 7-9(2010).
Get Citation
Copy Citation Text
Peng Jiang, Weixin Wang, Ning Zhang, Chengming Wang, Wei Huang, Gaojun Shi, Xiaojing Xu, Shuhui Gao. Preliminary Study on Determining the Sequence of Intersecting Lines Using Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2020, 57(22): 221101
Category: Imaging Systems
Received: Feb. 17, 2020
Accepted: Mar. 30, 2020
Published Online: Nov. 11, 2020
The Author Email: Ning Zhang (zhangning@cifs.gov.cn), Shuhui Gao (zhangning@cifs.gov.cn)