    Ultrasonic imaging models. (a) Traditional ultrasonic imaging model; (b) explosion reflection equivalent model
    Schematic diagram of sample structure used in numerical calculation
    Simulated time-domain data. (a) B-scan diagram of model with defect; (b) B-scan diagram of model without defect
    Difference between B-scan diagrams of models with and without defect
    Time domain diagrams obtained by different detections with same excitation. (a) Detection point is at -0.90mm; (b) detection point is at -0.15mm
    PSM calculation results for Fig. 2. (a) Side view of PSM result of shear wave; (b) side view of PSM result of longitudinal wave; (c) front view of PSM result of shear wave; (d) front view of PSM result of longitudinal wave
    Experimental setup
    Experimental B-scan diagram
    PSM reconstructed results for different numbers of frequencies. (a) SNR; (b) calculation time
    PSM results of shear wave for different frequency ranges. (a) Side view of PSM results from 3.1 to 16.9MHz; (b) side view of PSM results from 6.9 to 13.1MHz; (c) front view of PSM results from 3.1 to 16.9MHz; (d) front view of PSM results from 6.9 to 13.1MHz
    • Table 1. Material properties of high-strength steel

      View table

      Table 1. Material properties of high-strength steel

      ParameterValue
      Thermal expansion coefficient /K-11.23×10-5
      Young’s modulus /MPa2.0×105
      Poisson’s ratio0.30
      Lamé constant λ /(N·m2)1.5×1011
      Lamé constant μ /(N·m2)7.5×1010
      Density /(kg·m-3)7.85×103
    • Table 2. Parameters of pulsed laser

      View table

      Table 2. Parameters of pulsed laser

      ParameterValue
      Duration /ns10
      Spot radius /μm50
      Energy density /(J·m-2)3.82×104
    • Table 3. Basic structural parameters of model

      View table

      Table 3. Basic structural parameters of model

      ParameterValue
      Sample width x /mm7.00
      Sample thickness z /mm2.60
      Defect diameter D0 /mm0.20
      Defect depth z1 /mm1.34
      Excitation detection interval Δx /mm0.10
    Tools

    Get Citation

    Copy Citation Text

    Chu Chen, Kaining Ying, Nian Liu, Lunan Dai, Weiwei Kan, Chenyin Ni. Application of Phase Shift Migration Method in Laser Ultrasonic SAFT[J]. Chinese Journal of Lasers, 2021, 48(3): 0304001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Jul. 24, 2020

    Accepted: Sep. 14, 2020

    Published Online: Jan. 14, 2021

    The Author Email: Kan Weiwei (chenyin.ni@njust.edu.cn), Ni Chenyin (chenyin.ni@njust.edu.cn)

    DOI:10.3788/CJL202148.0304001

    Topics