Laser & Optoelectronics Progress, Volume. 61, Issue 15, 1512001(2024)

Influence of Position Errors in Marker Points on Visual Adjustment Accuracy of Mirror Pose in Solar Dish Concentrator

Yaosong Hu, Jian Yan*, and Youduo Peng
Author Affiliations
  • School of Mechanical Engineering, Hunan University of Science and Technology, Xiangtan 411201, Hunan, China
  • show less
    Figures & Tables(14)
    38 kW dish Stirling power generation system. (a) Physical image; (b) (c) mirror unit support adjustment structure
    Ideal posture and error posture of the mirror unit
    Schematic diagram of the introduction of error sphere
    Mirror unit eliminates the error of the axis vector after three rotational movements
    Influence of position errors in different marker points on the focal axis deviation angle. (a) T1 marker point; (b) T2 marker point; (c) T3 marker point
    Mean value and variance of the focal axis deviation angle under position error of different marker points. (a) Mean value; (b) variance
    Proportion of different marker points with different error sizes that meet the calibration accuracy. (a) Errors of T1, T2, and T3 are within the range of 1‒5 mm; (b) errors of T1 and T2 are within the range of 2.3‒2.6 mm; (c) errors of T3 are within the range of 1.6‒1.9 mm
    Mean value and variance of the focal axis deviation angle for different marker points. (a) Mean values of T1 and T2; (b) variance of T1 and T2; (c) mean value of T3; (d) variance of T3
    Influence of different errors at the three marker points on the deflection angle of the focal axis
    Ratio of mean value and variance of the focal axis deviation angle under different position errors of three marker points to the alignment accuracy. (a) Mean value; (b) variance; (c) proportion of conformity adjustment accuracy
    Influence of different sizes of mirror units on the deflection angle of the focal axis
    Mean value, variance, and proportion of compliance of the deflection angle obtained from different sizes of mirror units. (a) Mean value; (b) variance; (c) proportion of compliance
    Spatial location map of the three marker points of the mirror unit simulated by the Matlab program. (a) Overall diagram; (b) detailed diagram
    Mean value and variance of deviation angle obtained from different initial poses of mirror units. (a) Mean value; (b) variance
    Tools

    Get Citation

    Copy Citation Text

    Yaosong Hu, Jian Yan, Youduo Peng. Influence of Position Errors in Marker Points on Visual Adjustment Accuracy of Mirror Pose in Solar Dish Concentrator[J]. Laser & Optoelectronics Progress, 2024, 61(15): 1512001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jul. 10, 2023

    Accepted: Aug. 22, 2023

    Published Online: Aug. 12, 2024

    The Author Email: Jian Yan (yanjian1988@hnust.edu.cn)

    DOI:10.3788/LOP231677

    CSTR:32186.14.LOP231677

    Topics