Optics and Precision Engineering, Volume. 32, Issue 1, 53(2024)

Correction of probe alignment error for ZC1 worm gear profile measurement

Hui WAN... Jie TANG* and Zhaoyao SHI |Show fewer author(s)
Author Affiliations
  • Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing100124, China
  • show less
    Figures & Tables(15)
    Measurement principle of ZC worm tooth profile
    Coordinate system for grinding worm with grinding wheels
    Tooth profile measuring error
    Measurement error curves of tooth profile shape
    Influence of number of worm threads
    Influence of worm module
    Influence of pitch circle diameter
    Measured worm
    Profile deviation curves before correction
    Comparison of tooth profile deviation curves before and after correction
    Comparison of tooth profile deviation results
    • Table 1. Evaluation results of tooth profile deviations

      View table
      View in Article

      Table 1. Evaluation results of tooth profile deviations

      No.Fα1ffα1fHα1
      12.82.7-0.6
      22.62.7-0.7
      32.62.3-0.5
      42.62.4-0.6
      52.62.3-0.5
      Mean value2.62.5-0.6
    • Table 2. Tooth profile deviations before error correction

      View table
      View in Article

      Table 2. Tooth profile deviations before error correction

      No.Fα1ffα1fHα1
      14.03.21.7
      24.03.22.0
      33.82.72.1
      43.83.01.8
      53.62.71.8
      Mean value3.83.01.9
    • Table 3. Tooth profile deviations after error correction

      View table
      View in Article

      Table 3. Tooth profile deviations after error correction

      No.Fα1ffα1fHα1
      13.03.1-0.4
      23.03.1-0.1
      32.62.60.1
      42.82.9-0.3
      52.62.7-0.2
      Mean value2.82.8-0.2
    • Table 4. Correction result of tooth profile deviations

      View table
      View in Article

      Table 4. Correction result of tooth profile deviations

      ItemsFα1ffα1fHα1
      Initial state2.62.5-0.6
      Before correction of probe alignment errors3.83.01.9
      After correction of probe alignment errors2.82.8-0.2
      δ11.20.52.5
      δ20.20.30.4
    Tools

    Get Citation

    Copy Citation Text

    Hui WAN, Jie TANG, Zhaoyao SHI. Correction of probe alignment error for ZC1 worm gear profile measurement[J]. Optics and Precision Engineering, 2024, 32(1): 53

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jun. 18, 2023

    Accepted: --

    Published Online: Jan. 23, 2024

    The Author Email: Jie TANG (tangjie@bjut.edu.cn)

    DOI:10.37188/OPE.20243201.0053

    Topics