Chinese Journal of Lasers, Volume. 50, Issue 18, 1804002(2023)
Research on Laser Ultrasonic Total Focusing Imaging Method Based on ZYNQ Acceleration
[1] Yang C L. Research of automated ultrasonic non-destructive test of large complex geometry composite structures in aeronautic industry[D](2005).
[2] Wang J. Research on nondestructive testing for metal surface defect detection and rail tread residual stress determination using a laser ultrasonic technique[D](2016).
[3] Wang Y K, Liu J, Liu M et al. NDT technology research status of internal defect detection for oil and gas pipelines[J]. Corrosion & Protection, 35, 929-934(2014).
[4] Yao L F, Feng Y H, Wang L. Ultrasonic and ultrasonic measuring[J]. Journal of Shandong Institute of Light Industry (Natural Science Edition), 21, 67-69, 73(2007).
[5] Shan B H, Yu Y, Ou J P. Ultrasonic phased array inspection technology and its applications[J]. Nondestructive Testing, 26, 235-238(2004).
[6] Yang X X, Xue B, Jin S J et al. Application study on compressed sensing in ultrasonic phased array detection system[J]. Journal of Electronic Measurement and Instrumentation, 29, 1286-1294(2015).
[7] Zhang P H, Zhao Y, Li P et al. Research progress in ultrasonic imaging detection technology[J]. Laser & Optoelectronics Progress, 59, 0200003(2022).
[8] Sun B S. Applications and development of synthetic aperture imaging[J]. Journal of Applied Acoustics, 37, 787-793(2018).
[9] Shen Y D[M]. Modern nondestructive testing technology, 12-67(2012).
[10] Du Y H. Research on synthetic aperture focusing technology for ultrasonic imaging[D](2010).
[11] Chen C, Ying K N, Liu N et al. Application of phase shift migration method in laser ultrasonic SAFT[J]. Chinese Journal of Lasers, 48, 0304001(2021).
[12] Wang G, Huang L X, Wang Z G et al. A TFM based ultrasonic array detection and imaging method for concretes[J]. Technical Acoustics, 40, 482-489(2021).
[13] Holmes C, Drinkwater B W, Wilcox P D. Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation[J]. NDT & E International, 38, 701-711(2005).
[14] Hunter A J, Drinkwater B W, Wilcox P D. The wavenumber algorithm for full-matrix imaging using an ultrasonic array[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 55, 2450-2462(2008).
[15] Velichko A, Wilcox P D. Reversible back-propagation imaging algorithm for post-processing of ultrasonic array data[J]. IEEE Transaction on Ultrasonics, Ferroelectrics, and Frequency Control, 56, 2492-2503(2009).
[16] Hunter A J, Drinkwater B W, Wilcox P D. Autofocusing ultrasonic imagery for non-destructive testing and evaluation of specimens with complicated geometries[J]. NDT & E International, 43, 78-85(2010).
[17] Li C, Pain D, Wilcox P D et al. Imaging composite material using ultrasonic arrays[J]. NDT & E International, 53, 8-17(2013).
[18] Zhou Z G, Li Y, Zhou W B. Ultrasonic phased array post-processing imaging techniques: a review[J]. Journal of Mechanical Engineering, 52, 1-11(2016).
[19] Drinkwater B W, Bowler A I. Ultrasonic array inspection of the Clifton Suspension Bridge chain-links[J]. Insight, 51, 491-498(2009).
[20] Ran C. Fast ultrasonic total focus imaging based on FPGA[D], 13-24(2017).
[21] Jia L C, Chen S L, Bai Z L et al. Correction model and accelerating algorithm for ultrasonic total focusing method[J]. Chinese Journal of Scientific Instrument, 38, 1589-1596(2017).
[22] Shen Z H, Yuan L, Zhang H C[M]. Laser ultrasound in solids, 2-3(2015).
[23] Gao H D, López B. Development of single-channel and phased array electromagnetic acoustic transducers for austenitic weld testing[J]. Materials Evaluation, 68, 821-827(2010).
[24] Zhou Y, Li S X. Study of lamb wave dispersion characterization using multiplexed two-wave mixing interferometer[J]. Laser & Optoelectronics Progress, 58, 2319001(2021).
[25] Stratoudaki T, Clark M, Wilcox P D. Laser induced ultrasonic phased array using full matrix capture data acquisition and total focusing method[J]. Optics Express, 24, 21921-21938(2016).
[26] Stratoudaki T, Clark M, Wilcox P. Adapting the full matrix capture and the Total Focusing Method to laser ultrasonics for remote non destructive testing[C](2017).
[27] Zhou Z G, Sun G K, Li Y. Application of advanced nondestructive testing technologies for the detection of defects in composites[J]. Aeronautical Manufacturing Technology, 59, 30-35(2016).
[28] Velichko A, Wilcox P D. An analytical comparison of ultrasonic array imaging algorithms[J]. The Journal of the Acoustical Society of America, 127, 2377-2384(2010).
[29] Nikolov S I, Jensen J A, Tomov B G. Fast parametric beamformer for synthetic aperture imaging[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 55, 1755-1767(2008).
[30] Wu E H, Liu Y Q. General purpose computation on GPU[J]. Journal of Computer Aided Design & Computer Graphics, 16, 601-612(2004).
[31] Amaro J, Falcao G, Yiu B Y S et al. Portable parallel kernels for high-speed beamforming in synthetic aperture ultrasound imaging[C], 2688-2692(2013).
[32] Huang H J, Yu Y Y, Wang J J et al. Parallel design for ultrasound synthetic aperture imaging FPGA[C](2015).
[34] Sun X W. Properties of the focus triangle of hyperbola[J]. Mathematics Teaching Research, 38-39(1997).
[35] Bernstein J R, Spicer J B. Line source representation for laser-generated ultrasound in aluminum[J]. The Journal of the Acoustical Society of America, 107, 1352-1357(2000).
Get Citation
Copy Citation Text
Chanjuan Wu, Kaining Ying, Lunan Dai, Junfu Tan, Zhonghua Shen, Chenyin Ni. Research on Laser Ultrasonic Total Focusing Imaging Method Based on ZYNQ Acceleration[J]. Chinese Journal of Lasers, 2023, 50(18): 1804002
Category: Measurement and metrology
Received: Sep. 6, 2022
Accepted: Dec. 20, 2022
Published Online: Aug. 29, 2023
The Author Email: Ni Chenyin (chenyin.ni@njust.edu.cn)