Acta Optica Sinica, Volume. 42, Issue 5, 0512001(2022)

Passive Multi-Target Location Method Based on Rotating Laser Scanning

Boyuan Zhu1, Yongjie Ren1、*, Xianlong Duan2, Haifeng Zhou2, Zhengchao Wang3, Wenjie Shen1, and Jiarui Lin1
Author Affiliations
  • 1State Key Laboratory of Precision Measurement Technology and Instrument, Tianjin University, Tianjin 300072, China
  • 2CSSC Huangpu Wenchong Shipbuilding Company Limited, Guangzhou, Guangdong 510715, China
  • 3Dalian Shipbuilding Industry Co., Ltd, Dalian, Liaoning 116000, China
  • show less
    Figures & Tables(16)
    Principle of multi-target rendezvous positioning
    Ray path and region division of cube-corner prism. (a) Ray path; (b) incident zone/exit zone
    Reflection diagram and equivalent light path of scanning light. (a) Reflection diagram; (b) equivalent light path
    Geometric model of single point hyperboloid reflection receiver
    Optical model of rotating laser scanning detection
    Simulation of reflection receiving with different azimuths. (a1)(b1) -5°; (a2)(b2) 0°; (a3)(b3) 5°; (a4)(b4) 10°; (a5)(b5)15°; (a6)(b6) 20°
    Schematic diagram of measurement time error. (a) Active receiver mode; (b) prism mode
    Schematic diagram of scanning light sequence of transmitting station
    Experimental scene
    Comparison of signal measurement results at different distances. (a1)(a2) 4 m; (b1)(b2) 8 m
    Standard deviation of different locations
    • Table 1. Calibration results of structural parameters of object to be measuredunit: mm

      View table

      Table 1. Calibration results of structural parameters of object to be measuredunit: mm

      ParameterB1B2B3B4B5B6Ob
      xb547.36345.8189.02-422.76-706.60-1004.300.00
      yb807.52528.60335.20284.27-82.31-255.890.00
      zb386.46-30.72-443.91-107.36122.17-202.910.00
    • Table 2. Corresponding time values of prisms

      View table

      Table 2. Corresponding time values of prisms

      Scanning timePrism 1Prism 2Prism 3Prism 4Prism 5Prism 6
      Δt10.9039940.8885830.8826590.8777320.8608840.843388
      Δt20.1644040.1597180.1448910.1264590.1234580.120461
    • Table 3. Time values of optical signals to be matched

      View table

      Table 3. Time values of optical signals to be matched

      Optical signalLocation
      123
      10.1178030.1250960.119886
      20.1206650.1276920.122292
      30.1234910.1302470.124668
      40.1405200.1456560.138944
      50.1545280.1584630.150892
      60.1589790.1625420.154712
      70.8427010.8517760.848227
      80.8589690.8665200.861905
      90.8746620.8807650.875142
      100.8791360.8847840.878843
      110.8847360.8899260.883651
      120.8991730.9030800.895896
    • Table 4. Time series matching results

      View table

      Table 4. Time series matching results

      Measuring pointLocation
      123
      Prism 1(0.899173, 0.158979)(0.903080, 0.162542)(0.895896, 0.154712)
      Receiver 1(0.899170, 0.158976)(0.903077, 0.162539)(0.895891, 0.154709)
      Prism 2(0.884736, 0.154528)(0.889926, 0.158463)(0.883651, 0.150892)
      Receiver 2(0.884733, 0.154525)(0.889923, 0.158461)(0.883647, 0.150890)
      Prism 3(0.879136, 0.140520)(0.884784, 0.145656)(0.878843, 0.138944)
      Receiver 3(0.879132, 0.140516)(0.884780, 0.145652)(0.878839, 0.138941)
      Prism 4(0.874662, 0.123491)(0.880765, 0.130247)(0.875142, 0.124668)
      Receiver 4(0.874660, 0.123487)(0.880771, 0.130242)(0.875138, 0.124663)
      Prism 5(0.858969, 0.120665)(0.866522, 0.127692)(0.861905, 0.122292)
      Receiver 5(0.858965, 0.120662)(0.866517, 0.127688)(0.861901, 0.122289)
      Prism 6(0.842701, 0.117803)(0.851776, 0.125096)(0.848227, 0.119886)
      Receiver 6(0.842698, 0.117801)(0.851772, 0.125092)(0.848223, 0.119881)
    • Table 5. Coordinate measurement results

      View table

      Table 5. Coordinate measurement results

      LocationCoordinate /mmError /mm
      xyzΔxΔyΔz
      13904.96-2197.95240.930.37-0.51-0.40
      24418.96-2314.99248.220.39-0.350.42
      34763.94-2607.79254.340.540.280.58
      44883.87-3291.28256.140.41-0.12-0.31
      55403.99-3593.36259.11-0.22-0.30-0.33
      65749.52-3974.67263.04-0.37-0.39-0.36
      76128.32-4377.98268.78-0.33-0.27-0.32
      86170.88-4997.14266.78-0.490.350.73
      96421.57-5383.60267.33-0.570.670.64
      106951.27-5630.32263.59-0.430.790.34
    Tools

    Get Citation

    Copy Citation Text

    Boyuan Zhu, Yongjie Ren, Xianlong Duan, Haifeng Zhou, Zhengchao Wang, Wenjie Shen, Jiarui Lin. Passive Multi-Target Location Method Based on Rotating Laser Scanning[J]. Acta Optica Sinica, 2022, 42(5): 0512001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jul. 28, 2021

    Accepted: Sep. 8, 2021

    Published Online: Mar. 8, 2022

    The Author Email: Ren Yongjie (yongjieren@tju.edu.cn)

    DOI:10.3788/AOS202242.0512001

    Topics