Acta Optica Sinica, Volume. 42, Issue 5, 0514003(2022)

Backscatter Diagnostic System Implemented on Cluster Platform of 100 kJ Laser Facility and Experiment

Tao Xu*, Yulong Li, Xincheng Liu, Xiangming Liu, Zhichao Li, Tao Gong, Xiaoshi Peng, Ping Li, Dong Yang, Feng Wang**, and Jiamin Yang
Author Affiliations
  • Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, Sichuan 621900, China
  • show less
    Figures & Tables(11)
    Geometric optical arrangement diagram of laser beam platform
    General layout diagram of cluster platform scattered light diagnostic system
    Diffuse reflector structure used by different subsystems. (a) NBS1; (b) NBS2; (c) FABS
    Diagnostic optical path structure of NBS1
    Diagnostic optical path structure of NBS2 and FABS. (a) NBS2; (b) FABS
    Cluster physics experiment target and laser power parameters. (a) Back cover Au cavity; (b) laser power density curve with time
    Calculation results of plasma conditions at different moment. (a) 1.3 ns; (b) 2.3 ns; (c) 3.3 ns; (d) 4.3 ns
    Calculation results of spatial distribution of SBS scattered light under different mechanisms. (a) Subbeam mechanism; (b) bunching mechanism; (c) sharing of plasma waves; (d) sharing of scattered light
    Measurement results of typical spatial distribution of SBS scattered light. (a) Jigsaw results of FABS and NBS2 measurements at normalized strength; (b) NBS1 measurement results
    Typical time waveform and time-resolved spectral measurement results of SBS scattering light. (a) Time waveform; (b) time-resolved spectrum
    • Table 1. Geometrical optical parameters of imaging mirror arrays in three diagnostic subsystems

      View table

      Table 1. Geometrical optical parameters of imaging mirror arrays in three diagnostic subsystems

      Lens groupObject filed /(mm×mm)Magnification ratioWorking distance /mmObject resolution /mm
      NBS1-SBS305×3050.04001415>0.160
      NBS1-SRS305×3050.04001360>0.250
      NBS2-SBS610×6100.02001850>0.625
      NBS2-SRS610×6100.02001850>0.625
      FABS-SBS2600×16400.00456000>1.200
      FABS-SRS2600×16400.00456000>1.200
    Tools

    Get Citation

    Copy Citation Text

    Tao Xu, Yulong Li, Xincheng Liu, Xiangming Liu, Zhichao Li, Tao Gong, Xiaoshi Peng, Ping Li, Dong Yang, Feng Wang, Jiamin Yang. Backscatter Diagnostic System Implemented on Cluster Platform of 100 kJ Laser Facility and Experiment[J]. Acta Optica Sinica, 2022, 42(5): 0514003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Lasers and Laser Optics

    Received: Jul. 25, 2021

    Accepted: Sep. 10, 2021

    Published Online: Mar. 8, 2022

    The Author Email: Xu Tao (xutzo@163.com), Wang Feng (xiaozei7566@163.com)

    DOI:10.3788/AOS202242.0514003

    Topics