Acta Optica Sinica, Volume. 43, Issue 12, 1212005(2023)
Prelaunch Radiometric Characterization and Calibration for Long Wave Infrared Band of FY-4B GHI
[3] Yoon H W, Kacker R N. Guidelines for radiometric calibration of electro-optical instruments for remote sensing: NISTHB 157[R](2015).
[4] Li X J, Wang B Y, Wu Y P et al. Study on the improvement of scan mirror thermal radiation correction on the calibration accuracy of FY-4A AGRI[J]. Journal of Infrared and Millimeter Waves, 41, 608-617(2022).
[5] Wang J, Liu C B, Yang L et al. Calculation of geostationary satellites' nominal fixed grid and its application in FY-4A advanced geosynchronous radiation imager[J]. Acta Optica Sinica, 38, 1211001(2018).
[6] Li L, Ni Z Y, Qi C L et al. Pre-launch radiometric calibration of geostationary interferometric infrared sounder on FengYun-4B satellite[J]. Acta Optica Sinica, 42, 0630001(2022).
[7] Chen F S, Hu Z Y, Li X Y et al. Research on wide-range and high-resolution thermal infrared remote sensing imaging technology[J]. Chinese Journal of Lasers, 48, 1210002(2021).
[8] Dong Y H. FY-4 meteorological satellite and its application prospect[J]. Aerospace Shanghai, 33, 1-8(2016).
[9] Grant B G[M]. Field guide to radiometry, 73-84(2011).
[10] Datla R, Shao X, Cao C Y et al. Comparison of the calibration algorithms and SI traceability of MODIS, VIIRS, GOES, and GOES-R ABI sensors[J]. Remote Sensing, 8, 126(2016).
[11] Weinreb M, Jamieson M, Fulton N et al. Operational calibration of Geostationary Operational Environmental Satellite-8 and-9 imagers and sounders[J]. Applied Optics, 36, 6895-6904(1997).
[12] Chiang K F, Xiong X X. Pre-launch characterization of aqua MODIS scan mirror response versus scan angle for thermal emissive bands[J]. Proceedings of SPIE, 6677, 66771J(2007).
[13] Xiong X, Chiang K, Chen N et al. Results and lessons from MODIS thermal emissive bands calibration: pre-launch to on-orbit[J]. Proceedings of SPIE, 6296, 62960A(2006).
[14] Xiong X X, Sun J Q, Wu A S et al. Terra and Aqua MODIS calibration algorithms and uncertainty analysis[J]. Proceedings of SPIE, 5978, 59780V(2005).
[15] Guenther B, Xiong X, Barnes W L et al. A calibration algorithm design and analysis for VIIRS Thermal Emissive Bands based on the EOS MODIS approach[C], 3036-3038(2003).
[16] Oudrari H, McIntire J, Xiong X X et al. Prelaunch radiometric characterization and calibration of the S-NPP VIIRS sensor[J]. IEEE Transactions on Geoscience and Remote Sensing, 53, 2195-2210(2015).
[17] Zhou S C[M]. Introduction to advanced infrared photoelectric engineering, 21-27, 235-239(2014).
[18] Chen B L, Li X Y[M]. Infrared imaging detectors for space applications, 145-147(2016).
[20] Li W L, Li X J, Tu H W et al. Relationship between spectral response non-uniformity of pixels and stripe noise[J]. Acta Optica Sinica, 42, 1211001(2022).
[21] Johnson R X, Weinreb M P. GOES-8 imager midnight effects and slope correction[J]. Proceedings of SPIE, 2812, 596-607(1996).
[22] Baker N. Joint Polar Satellite System (JPSS) VIIRS Radiometric Calibration Algorithm Theoretical Base Document (ATBD): 423-ATBD-001[R], 1-195(2014).
Get Citation
Copy Citation Text
Xiuju Li, Qi Cao, Shutian Zhou, Jing Qian, Baoyong Wang, Yaopu Zou, Jing Wang, Xia Shen, Changpei Han, Lizhi Wang, Yuxiang Zhou, Panpan Li. Prelaunch Radiometric Characterization and Calibration for Long Wave Infrared Band of FY-4B GHI[J]. Acta Optica Sinica, 2023, 43(12): 1212005
Category: Instrumentation, Measurement and Metrology
Received: Sep. 7, 2022
Accepted: Dec. 7, 2022
Published Online: Jun. 20, 2023
The Author Email: Wang Jing (wjing@cma.gov.cn), Shen Xia (shenxia@mail.sitp.ac.cn)