Acta Laser Biology Sinica, Volume. 30, Issue 6, 481(2021)

X-ray-induced Acoustic Computed Tomography and Its Biomedical Applications

KONG Xin1, ZHANG Xingchao1, GUO Shanshan1, WANG Hanqiu1, LYU Zhiwei1, XUE Yanling2, XIU Junshan1, ZHAO Yue1, and LIU Huiqiang1,2,3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(28)

    [1] [1] RROENTGEN W C. On a new kind of rays [J]. Resonance, 1896, 3(59): 227-231.

    [2] [2] GORELICK S, VILA-COMAMALA J, GUZENKO V A, et al. High-efficiency Fresnel zone plates for hard X-rays by 100 keV e-beam lithography and electroplating [J]. Journal of Synchrotron Radiation, 2011, 18(3): 442-446.

    [3] [3] WILKINS S W, GUREYEV T E, GAO D, et al. Phase-contrast imaging using polychromatic hard X-rays [J]. Nature, 1996, 384(6607): 335-338.

    [4] [4] LIU H, WU X, XIAO T. Technical note: synchrotron-based high-energy X-ray phase sensitive microtomography for biomedical research [J]. Medical Physics, 2015, 42(10): 5595.

    [5] [5] HOUNSFIELD G N. Computerized transverse axial scanning (tomography): Part 1 [J]. The British Journal of Radiology, 1973, 46(552): 1016-1022.

    [6] [6] CORMACK A M. Representation of a function by its line integrals, with some radiological applications [J]. Journal of Applied Physics, 1963, 34(9): 2722-2727.

    [7] [7] LIU H, REN Y, ZHOU G, et al. Feasibility study of phase-shift absorption duality algorithm for X-ray mixed contrast quantitative micro-CT [J]. Journal of Physics, 2012, 61(7): 544-552.

    [8] [8] XIANG L, HAN B, CARPENTER C, et al. X-ray acoustic computed tomography with pulsed X-ray beam from a medical linear accelerator [J]. Medical Physics, 2013, 40(1): 010701.

    [9] [9] XU L, BAI L, YAN T, et al. Application of synchrotron radiation low-angle and wide-angle X-ray scattering in polymer materials research [J]. Polymer Bulletin, 2010, 10(12): 1-26.

    [10] [10] TANG S, RAMSEYER C, SAMANT P, et al. X-ray-induced acoustic computed tomography of concrete infrastructure [J]. Applied Physics Letters, 2018, 112(6): 063504.

    [11] [11] KIM K Y, SACHSE W. X‐ray generated ultrasound [J]. Applied Physics Letters, 1983, 43(12): 1099-1101.

    [12] [12] DING W, JI Z, LIU C, et al. Sensing non-light-absorbing media via thermally modulated photoacoustic measurements [J]. Applied Physics Letters, 2021, 118(2): 023701.

    [13] [13] ZHAO Y, YANG S, CHEN C, et al. Simultaneous optical absorption and viscoelasticity imaging based on photoacoustic lock-in measurement[J]. Optics Letters, 2014, 39(9): 2565-2568.

    [14] [14] ZHAO Y, YANG S, WANG Y, et al. In vivo blood viscosity characterization based on frequency-resolved photoacoustic measurement [J]. Applied Physics Letters, 2018, 113(14): 143703.

    [15] [15] WANG S, ECHEVERRY J, TREVISI L, et al. Ultrahigh resolution pulsed laser-induced photoacoustic detection of multi-scale damage in CFRP composites [J]. Applied Sciences, 2020, 10(6): 2106.

    [16] [16] XIANG L, TANG S, AHMAD M, et al. High resolution X-ray-induced acoustic tomography [J]. Scientific Reports, 2016, 6(1): 1-6.

    [17] [17] HICKLING S, LEI H, HOBSON M, et al. Experimental evaluation of X‐ray acoustic computed tomography for radiotherapy dosimetry applications [J]. Medical Physics, 2016, 44(2): 608-617.

    [18] [18] TANG S, NGUYEN D H, ZARAFSHANI A, et al. X-ray-induced acoustic computed tomography with an ultrasound transducer ring-array [J]. Applied Physics Letters, 2017, 110(10): 103504.

    [19] [19] BOWEN T, CHEN C X, LIEW S C, et al. Observation of ultrasonic emission from edges of therapeutic X-ray beams [J]. Physics in Medicine & Biology, 1991, 36(4): 537-539.

    [20] [20] ZHAO Y, WANG S, MERRILL J A, et al. Triplex radiometric, photoacoustic, and ultrasonic imaging based on single-pulse excitation [J]. Optics Letters, 2020, 45(7): 1703-1706.

    [21] [21] SAMANT P, TREVISI L, JI X, et al. X-ray induced acoustic computed tomography [J]. Photoacoustics, 2020, 19: 100177.

    [22] [22] LIU G, QIAN J, LI X, et al. Signal detection and simulation of X-ray photoacoustic imaging [J]. Journal of Shenzhen University, 2018, 35(3): 324-330.

    [23] [23] LI Y, SAMANT P, WANG S, et al. 3-D X-ray-induced acoustic computed tomography with a spherical array: a simulation study on bone imaging [J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2020, 67(8): 1613-1619.

    [24] [24] TANG S, YANG K, CHEN Y, et al. X‐ray‐induced acoustic computed tomography for 3D breast imaging: a simulation study [J]. Medical Physics, 2018, 45(4): 1662-1672.

    [25] [25] WANG M, SAMANT P, WANG S, et al. Toward in vivo dosimetry for prostate radiotherapy with a transperineal ultrasound array: a simulation study [J]. IEEE Transactions on Radiation and Plasma Medical Sciences, 2020, 5(3): 373-382.

    [26] [26] LEI H, ZHANG W, ORAIQAT I, et al. Towards in vivo dosimetry in external beam radiotherapy using X-ray acoustic computed tomography: a soft-tissue phantom study validation [J]. Medical Physics, 2018, 45(9): 4191-4200.

    [27] [27] LASCAUD J, DASH P, WIESER H P, et al. Investigating the accuracy of co-registered ionoacoustic and ultrasound images in pulsed proton beams [J]. Physics in Medicine and Biology, 2021, 66(18): 185007.

    [28] [28] AHMAD M, XIANG L, YOUSEFI S, et al. Theoretical detection threshold of the proton‐acoustic range verification technique [J]. Medical Physics, 2015, 42(10): 5735-5744.

    Tools

    Get Citation

    Copy Citation Text

    KONG Xin, ZHANG Xingchao, GUO Shanshan, WANG Hanqiu, LYU Zhiwei, XUE Yanling, XIU Junshan, ZHAO Yue, LIU Huiqiang. X-ray-induced Acoustic Computed Tomography and Its Biomedical Applications[J]. Acta Laser Biology Sinica, 2021, 30(6): 481

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 22, 2021

    Accepted: --

    Published Online: Feb. 11, 2022

    The Author Email:

    DOI:10.3969/j.issn.1007-7146.2021.06.001

    Topics