Acta Optica Sinica, Volume. 44, Issue 12, 1212001(2024)

Computation Model for Calculating Infrared Radiance of Aerial Target Based on Each Pixel Calibration of Refrigeration Infrared System

Shiqi Gan*, Weichao Wang, Guangfu Yuan, Peijian Wu, and Tongbang Wu
Author Affiliations
  • 95859 Army, People s Liberation Army of China, Jiuquan 735018, Gansu, China
  • show less
    Figures & Tables(10)
    Schematic of near-extended-source method
    Imaging sketch of target on infrared detector and region division
    Calibration gain coefficient matrix value Gx,y and bias matrix value Bx,y of refrigeration infrared system at different ambient temperatures. (a) Calibration gain coefficient matrix value; (b) bias matrix value
    Comparison between traditional calibration results and each pixel calibration results. (a) Traditional calibration results; (b) gain coefficient matrix values; (c) bias matrix values
    Diagram of equivalent data process method
    Contrast between traditional calibration result and each pixel calibration result. (a) Traditional calibration result; (b) gain coefficient matrix value; (c) bias matrix value
    Diagram of field verification experiment
    Field verification experiment data
    • Table 1. Comparison of calculation results between traditional method and ours

      View table

      Table 1. Comparison of calculation results between traditional method and ours

      Temperature /Target radiance L /(Wm-2sr-1Relative error δ /%Deviation degree of error γ
      T1T2Theoretical valueTraditional methodOursTraditional methodOursTraditional methodOurs
      60403.763.583.85-4.792.390.2250.153
      80506.617.496.6013.31-0.150.9070.225
      1008010.9611.9410.768.94-1.820.9950.221
      80406.617.666.7415.891.971.0570.172
      1005010.9611.6810.856.57-1.000.7420.158
      60503.763.993.726.12-1.060.2560.110
      50402.762.552.76-7.6100.2510.098
      1004010.969.3010.81-15.15-1.371.6750.180
    • Table 2. Comparison of calculation results between traditional method and ours

      View table

      Table 2. Comparison of calculation results between traditional method and ours

      Temperature /Target radiance L /(Wm-2sr-1Relative error δ /%Deviation degree of error γ
      T1T2Theoretical valueTraditional methodOursTraditional methodOursTraditional methodOurs
      1109013.8315.4812.8011.93-7.451.681.08
      1309021.3022.9120.207.56-5.161.691.21
      13011021.3025.6621.1120.47-0.894.390.54
      1509031.5332.4829.723.01-5.741.121.90
      15013031.5337.7830.5619.82-3.086.271.13
      15011031.5335.2330.6211.73-2.893.741.08
      20013072.9476.9269.495.46-4.734.203.69
      20015072.9481.2970.2811.45-3.658.462.96
    Tools

    Get Citation

    Copy Citation Text

    Shiqi Gan, Weichao Wang, Guangfu Yuan, Peijian Wu, Tongbang Wu. Computation Model for Calculating Infrared Radiance of Aerial Target Based on Each Pixel Calibration of Refrigeration Infrared System[J]. Acta Optica Sinica, 2024, 44(12): 1212001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jul. 10, 2023

    Accepted: Aug. 15, 2023

    Published Online: Jun. 12, 2024

    The Author Email: Gan Shiqi (gsq1342@163.com)

    DOI:10.3788/AOS231239

    Topics