Acta Optica Sinica, Volume. 37, Issue 10, 1034001(2017)

Optimized Iterative Method for Projection Decomposition of X-Ray Dual-Energy Computed Tomography

Baolei Li*, Pingyu Zhang, Bin Li, Yang Mo, Bo Meng, and Yaojun Zhang
Author Affiliations
  • Security Inspection Division, First Research Institute of the Ministry of Public Security of PRC, Beijing 100048, China
  • show less
    References(22)

    [1] Fessler J A, Elbakri I, Sukovic P et al. Maximum-likelihood dual-energy tomographic image reconstruction[C]. SPIE, 4684, 38-49(2002).

    [4] Eger L, Do S, Karl W C et al[2017-04-10]. Implementation of an image-based dual-energy method for explosives detection on real CT data[2017-04-10]. http: ∥www.censsis.neu.edu/RICC/2009/posters/final/ALERTp10.pdf..

    [5] Liu X, Primak A N, Yu L F et al. Quantitative imaging of chemical composition using dual-energy, dual-source CT[C]. SPIE, 6913, 69134Z(2008).

    [9] Chuang K S. Theory and applications of dual energy technique[D]. Los Angeles: University of California(1986).

    [13] Tang S J, Mou X Q, Luo T. An iteration algorithm in dual-energy X-ray imaging based on polychromatic physics model[C]. SPIE, 6142, 61422R(2006).

    [14] Zou Y, Sliver M D. Analysis of fast kV-switching in dual-energy CT using a pre-reconstruction decomposition technique[C]. SPIE, 6913, 691313(2008).

    [18] Ying Z R, Naidu R, Guilbert K et al. Dual energy volumetric X-ray tomographic sensor for luggage screening[C]. IEEE Sensors Applications Symposium, 1-6(2007).

    [20] Naidu R, Bechwati I. -03-27[P]. Crawford C R. Decomposition of multi-energy scan projections using multi-step fitting: US7197172.(2007).

    [21] Li Baolei, Zhang Yaojun. Projection decomposition algorithm of X-ray dual-energy computed tomography based on projection matching[J]. Acta Optica Sinica, 31, 0311002(2011).

    [22] Li Lei, Wang Linyuan, Cai Ailong et al. Projection decomposition algorithm for X-ray dual-energy computed tomography based on isotransmission line fitting[J]. Acta Optica Sinica, 36, 0834001(2016).

    CLP Journals

    [1] Geng Niu, Junbiao Liu, Weixia Zhao, Li Han, Yutian Ma. Effect of Focused Bombarding Electron Beam on Transmission Microfocus X-Ray Source[J]. Acta Optica Sinica, 2019, 39(6): 0634001

    [2] Geng Niu, Junbiao Liu, Weixia Zhao, Li Han, Yutian Ma. Effect of Focused Bombarding Electron Beam on Transmission Microfocus X-Ray Source[J]. Acta Optica Sinica, 2019, 39(6): 0634001

    Tools

    Get Citation

    Copy Citation Text

    Baolei Li, Pingyu Zhang, Bin Li, Yang Mo, Bo Meng, Yaojun Zhang. Optimized Iterative Method for Projection Decomposition of X-Ray Dual-Energy Computed Tomography[J]. Acta Optica Sinica, 2017, 37(10): 1034001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: X-Ray Optics

    Received: Apr. 12, 2017

    Accepted: --

    Published Online: Sep. 7, 2018

    The Author Email: Baolei Li (baolei_li@aliyun.com)

    DOI:10.3788/AOS201737.1034001

    Topics