    Overall plan for RCS flow measurement and data processing
    Schematic of flow measurement transmitters of RCS Loop I
    Flowchart for RCS bend pipe flow calculation
    Measurement of pressure difference for RCS cold (a) and hot (b) leg flow
    Flow measurement data and expected data for each measuring method
    • Table 1. Differential pressure measurement and flow calculation during HFT and start-up test

      View table
      View in Article

      Table 1. Differential pressure measurement and flow calculation during HFT and start-up test

      测点

      Test position

      不确定度

      Uncertainty

      热试计算值HFT calculated flow / m3∙hr-1热试总流量HFT total flow / m3∙hr-1启动试验计算值Start-up test calculated flow / m3∙hr-1启动试验总流量Start-up test total flow / m3∙hr-1

      压力容器TFT115

      RV TFT115

      ±5.26%71 13171 52371 801.596 871 212.962 9

      蒸发器TFT113

      SG TFT113

      ±10.70%37 04473 702

      主泵TFT101

      RCP TFT101

      ±1.54%18 10071 840

      热管FT1

      HL FT1

      ±13.09%32 15432 280.537 229.208 074 570.983 3

      热管FT2

      HL FT2

      ±13.07%32 550

      热管FT3

      HL FT3

      ±13.10%31 949

      热管FT4

      HL FT4

      ±13.07%32 469

      热管TFT109

      HT TFT109

      ±12.68%32 82232 398.536 890.125 373 731.652 4

      热管TFT110

      HT TFT110

      ±12.68%31 975

      冷管FT171

      CL FT171

      ±4.28%18 00169 36918 718.055 771 950.906 8

      冷管TFT105

      CL TFT105

      ±4.15%18 43470 95118 618.200 970 633.531 0

      RCS总流量值

      RCS Total Flow

      ±1.32%71 546
    • Table 2. Differential pressure measurement, flow calculation, and weighting factor during HFT

      View table
      View in Article

      Table 2. Differential pressure measurement, flow calculation, and weighting factor during HFT

      测量方式Test method测量流量Test flow / m3∙hr-1不确定度Uncertainty / %权重因子Weighting factor
      RV压差 RV Dp71 523.00±5.250.061 6
      SG压差 SG Dp73 702.00±10.760.010 2
      RCP压差 RCP Dp71 840.00±1.460.809 8
      冷管压差 Cold Leg Dp70 160.00±4.140.106 1
      热管压差 Hot Leg Dp62 393.00±12.680.012 3
      总流量 Total Flow / m3∙hr-171 546.00±1.32
    • Table 3. Calibrated RCS bend pipe flow coefficients

      View table
      View in Article

      Table 3. Calibrated RCS bend pipe flow coefficients

      永久仪表Permanent transmitter热试流量系数HFT flow coefficient

      启动流量系数

      PFT flow coefficient

      最终流量系数Final flow coefficient
      环路I热管1 Loop I HLeg11.5281.5231.525
      环路I热管2 Loop I HLeg21.5441.5331.537
      环路I热管3 Loop I HLeg31.5281.5221.524
      环路I热管4 Loop I HLeg41.5441.5381.540
      环路I冷管1 Loop I CLeg 12.6312.6362.632
      环路I冷管2 Loop I CLeg 22.3892.3912.389
    Tools

    Get Citation

    Copy Citation Text

    Hui LUO. Systematic measurement method for primary coolant flow rate in advanced passive nuclear power units[J]. NUCLEAR TECHNIQUES, 2023, 46(10): 100602

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Jun. 10, 2023

    Accepted: --

    Published Online: Nov. 21, 2023

    The Author Email:

    DOI:10.11889/j.0253-3219.2023.hjs.46.100602

    Topics