Infrared and Laser Engineering, Volume. 44, Issue 3, 897(2015)

Linewidth rapid measurement of narrow fiber laser by spectrum analyzer

An Panlong1,2、*, Zhao Ruijuan2, Zheng Yongqiu3, Xue Chenyang1,3, Zhang Chengfei1, Li Xiaofeng1, Yan Shubin1,3, and Liu Jun1,3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(11)

    [1] [1] Yang Xiufeng, Jia Guoqiang, Tong Zhengrong, et al. Narrow line width fiber laser measurement line width of the research [J]. Optical Communication Technology, 2012, 36(7): 4-6.(in Chinese)

    [2] [2] He X, Fang X, Liao C, et al. A tunable and switchable single longitudinal mode dual wavelength fiber laser with a simple linear cavity [J]. Optics Express, 2009, 17(24): 21773-21781.

    [3] [3] Tian Pengfei, Sun Xinxin. Single longitudinal mode and narrow linewidth fiber lasers [J]. Optical Fiber & Electric Cable, 2010(5): 16-19. (in Chinese)

    [4] [4] Takakura T, Iga K, Tako T. Linewidth measurement of a single longitudinal mode AlGaAs laser with a Fabry-Perot interferometer[J]. Japanese Journal of Applied Physics, 1980, 19(12): 725-727.

    [5] [5] Okoshi T, Kikuchi K, Nakayama A. Novel method for high resolution measurement of laser output spectrum[J]. Electronics Letters, 1980, 16(16): 630-631.

    [6] [6] Richter L E, Mandelberg H I, Kruger M S, et al. Linewidth determination from self-heterodyne measurements with subcoherence delay times[J]. IEEE Journal of Quantum Electronics, 1986, 22(11): 2070-2074.

    [7] [7] Xie Donghong, Deng Dapeng, Guo Li, et al. Linewidth measurement method of narrow line width lasers[J]. Laser & Optoelectronics Progress, 2013, 50(1): 010006. (in Chinese)

    [8] [8] Gallion P B, Debarge G. Quantum phase noise and field correl-ation in single frequency semiconductor laser systems[J]. IEEE Journal of Quantum Electronics, 1984, 20(4): 343-349.

    [9] [9] Shi Hanxing, Wu Tie. Basic requirements of the delayed self-heterodyne spectrum measurement system[J]. Journal of Beijing University of Posts and Telecommunications, 1997, 20(2): 55-60. (in Chinese)

    [10] [10] Xiao Huaju, Wang Xiang, Ma Yun, et al. Linewidth measu-rement of narrow fiber laser based on the DSHI [J]. Optic-Electronic Engineering, 2010, 37(8): 57-61. (in Chinese)

    [11] [11] Jia Yudong, Ou Pan, Yang Yuanhong, et al. Short fiber delayed self-heterodyne interferometer for ultra-narrow laser linewidth measurement[J]. Beijing University of Aeronautics and Astronautics, 2008, 34(5): 568-571. (in Chinese)

    CLP Journals

    [1] Hu Xuan, Li Daojing, Tian He, Zhao Xufeng. Impact and correction of phase error in ladar signal on synthetic aperture imaging[J]. Infrared and Laser Engineering, 2018, 47(3): 306001

    Tools

    Get Citation

    Copy Citation Text

    An Panlong, Zhao Ruijuan, Zheng Yongqiu, Xue Chenyang, Zhang Chengfei, Li Xiaofeng, Yan Shubin, Liu Jun. Linewidth rapid measurement of narrow fiber laser by spectrum analyzer[J]. Infrared and Laser Engineering, 2015, 44(3): 897

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 激光与光电子技术应用

    Received: Jul. 5, 2014

    Accepted: Aug. 18, 2014

    Published Online: Jan. 26, 2016

    The Author Email: Panlong An (panlong_an@nuc.edu.cn)

    DOI:

    CSTR:32186.14.

    Topics