Acta Optica Sinica, Volume. 29, Issue 7, 1956(2009)

Optical Fiber Sensor for Liquid Refractive Index Based on Fiber Optic Taper

Xiong Yikun* and Huang Xuguang
Author Affiliations
  • [in Chinese]
  • show less
    References(16)

    [6] [6] Schubert T., Haase N., Kuck H. et al.. Refractive-index measurements using an integrated Mach-Zehnder interferometer[J]. Sensors and Actuators A, 1997, 60(1~3): 108~112

    [9] [9] Fan Yanbin, Wang Zhenyan. Research on the Relationship between Interference Pattern and Refractive Index with Febry-Porot Interferometor[J]. Chinese J. Quant. Electron., 1999, 16(5): 466~469

    [10] [10] Zhaobing Tian, Scott S-H.Yam, Hans--Peter Loock et al.. Refractive index sensor based on an abrupt taper Michelson interferometer in a single-mode fiber[J]. Opt. Lett., 2008, 33(10): 1105~1107

    [11] [11] Zhaobing Tian, Scott S-H.Yam, Jack Barnes et al.. Refractive Index Sensing With Mach–Zehnder Interferometer Based on Concatenating Two Single-Mode Fiber Tapers[J]. IEEE Photon. Technol. Lett., 2008, 20(8): 626~628

    [12] [12] J. F. Ding, A. P. Zhang, L. Y. Shao et al.. Fiber-Taper Seeded Long-Period Grating Pair as a Highly Sensitive Refractive-Index Sensor[J]. IEEE Photon. Technol. Lett., 2005, 17(6): 1247~1249

    [13] [13] Pavel Polynkin, Alexander Polynkin, N. Peyghambarian et al.. Evanescent field-based optical fiber sensing device for measuring the refractive index of liquids in microfluidic channels[J]. Opt. Lett., 2005, 30(11): 1273~1275

    [14] [14] Liao Yanbiao. Fiber Optics[M]. Beijing: Tsinghua Publishing House, 2000, 41~43

    [15] [15] Yan Fengping, Shan Ying, Jian Shuisheng et al.. Numerical analysis of the mode field radius for the square law and step index fiber[J]. Optical Technique, 2000, 26(1): 66~70

    [16] [16] Su Hui, Huang Xuguang. Fresnel-reflection-based fiber sensor for on-line measurement of solute concentration in solutions[J]. Sensors & Actuators: B, 2007, 126(2): 579~582

    CLP Journals

    [1] Fu Haiwei, Xu Shichao, Qiao Xueguang, Liu Yinggang, Zhou Hong, Luo Mingshi, Qiu Shuwei. Coated and Tapered Fiber Transmission Characteristics Based on Temperature Variation[J]. Chinese Journal of Lasers, 2012, 39(3): 305001

    [2] Fu Xinghu, Yang Chuanqing, Wang Siwen, Xie Haiyang, Zhang Shunyang, Fu Guangwei, Bi Weihong. Refractive Index and Temperature Sensor of Tapered Triple Cladding Quartz Specialty Fiber[J]. Acta Optica Sinica, 2015, 35(12): 1206003

    [3] Fu Xinghu, Yang Chuanqing, Wang Siwen, Wen Jianxiang, Dong Yanhua, Fu Guangwei, Bi Weihong. Refractive Index and Curvature Insensitive PbS Fiber Temperature Sensor Based on Inter-modal Interference Principle[J]. Chinese Journal of Lasers, 2016, 43(12): 1210002

    [4] Chen Qianghua, Liu Jinghai, Luo Huifu, He Yongxi, Luo Jun, Wang Feng. Refractive Index Measurement System of Liquid Based on Surface Plasmon Resonance[J]. Acta Optica Sinica, 2015, 35(5): 512002

    [5] Liu Jianping, Liang Liping, Huang Yun, Jin Shilong. Application of the Optical Fiber Prober in Measuring Micro Deep Hole of Small Laser[J]. Chinese Journal of Lasers, 2011, 38(7): 708002

    [6] Jiang Weiwei, Zhao Ruifeng, Wei Yan, Jian Shuisheng. Spectral Characteristics of Bragg Fiber Grating Based on Fused Taper Fiber[J]. Chinese Journal of Lasers, 2010, 37(10): 2565

    [7] He Hualong, Feng Guoying, Deng Guoliang, Zhou Hao. Improvement of the Beam Quality Factor by Using Tapered Micro/Nano Fiber[J]. Chinese Journal of Lasers, 2011, 38(8): 805008

    Tools

    Get Citation

    Copy Citation Text

    Xiong Yikun, Huang Xuguang. Optical Fiber Sensor for Liquid Refractive Index Based on Fiber Optic Taper[J]. Acta Optica Sinica, 2009, 29(7): 1956

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: Aug. 4, 2008

    Accepted: --

    Published Online: Jul. 20, 2009

    The Author Email: Xiong Yikun (xyk117@163.com)

    DOI:

    Topics