High Power Laser and Particle Beams, Volume. 37, Issue 4, 044001(2025)

Alignment measurement and adjustment for the whole system of Yunguang II accelerator

Deyu He, Yixiang Hu, Shi Yang, Yawei Zhou, Aixu Zhong, Min Dong, Jiahui Yin, Weixi Luo, Jiangtao Zeng, and Peitian Cong
Author Affiliations
  • National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi’an 710024, China
  • show less
    Figures & Tables(8)
    Structure of Yunguang II accelerator and A-K gap formed by cavity & MITL
    Alignment measurement spot image and the results of generator output flanges
    Alignment measurement spot image and the results of cavity rails
    Target base mechanism and 12-stage cavities after adjustment
    Alignment measurement results of cavity coaxiality and axial position
    Alignment measurement results of MITL rails
    • Table 1. Allocation of core alignment errors

      View table
      View in Article

      Table 1. Allocation of core alignment errors

      cavity numbercavity coaxiality/mmcavity tilt/mmMITL coaxiality/mmMITL fixture position/mmtotal error/mmcriteria/mmextreme error rate/%
      10.30.40.60.51.81.56.0
      20.30.40.60.51.81.56.0
      30.50.41.00.52.42.54.8
      40.70.41.40.53.03.54.3
      50.90.41.50.53.33.53.7
      61.00.41.50.53.43.53.1
      71.00.41.50.53.43.52.8
      81.00.41.50.53.43.52.4
      91.00.41.50.53.43.52.3
      101.00.41.50.53.43.52.1
      111.00.41.50.53.43.51.9
      121.00.41.50.53.43.51.8
      extension1.00.41.50.53.43.51.7
    • Table 2. Allocation of fundamental alignment errors

      View table
      View in Article

      Table 2. Allocation of fundamental alignment errors

      No.measured objectmeasuring itemscriteria
      1generator output flangeverticality±0.1°
      2cavity railhorizontal position±1 mm
      height position±1 mm
      3cavityaxial position±5 mm
      4MITL railhorizontal position±3 mm
      height position±1 mm
    Tools

    Get Citation

    Copy Citation Text

    Deyu He, Yixiang Hu, Shi Yang, Yawei Zhou, Aixu Zhong, Min Dong, Jiahui Yin, Weixi Luo, Jiangtao Zeng, Peitian Cong. Alignment measurement and adjustment for the whole system of Yunguang II accelerator[J]. High Power Laser and Particle Beams, 2025, 37(4): 044001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 30, 2024

    Accepted: Mar. 24, 2025

    Published Online: May. 15, 2025

    The Author Email:

    DOI:10.11884/HPLPB202537.240396

    Topics