Acta Optica Sinica, Volume. 40, Issue 15, 1506001(2020)
Comparative Analysis of Strain Monitoring of the Installed Optical Fiber Composite Overhead Ground Wire Using BOTDA/R
[1] Chen Z X, Wang Y, Jiang H et al. Research on performance of icing OPGW cable and application of on-line monitoring technology[J]. Computer Engineering & Software, 41, 152-155(2020).
[2] Chen X H, Huang J H, Zhang J M et al. Analysis and suggestions on ice overloading of OPGW cables[J]. Telecommunications for Electric Power System, 29, 8-13,31(2008).
[3] Xu Z L, Zeng Y H, Guo S et al. Application of intelligent monitoring system for transmission lines based on image recognition technology[J]. Computer Systems & Applications, 29, 67-72(2020).
[4] Zhang Y. On-line monitoring system of conductor icing on overhead transmission lines[J]. High Voltage Engineering, 34, 1992-1995(2008).
[5] Li Y H, Han J Y, Wang T. Ice monitoring system of overhead electrical power lines[J]. Electric Power Automation Equipment, 29, 112-115(2009).
[6] Gong J G, Xu Q S, Hu X G. Real-time monitoring of transmission line ice-coating by simulation conductor[J]. Electric Power Construction, 31, 20-22(2010).
[7] Ogawa Y, Iwasaki J I, Nakamura K. A multiplexing load monitoring system of power transmission lines using fiber Bragg grating. [C]∥12th International Conference on Optical Fiber Sensors. Washington, D.C.: OSA, 468-471(1997).
[8] Gangopadhyay T K, Paul M C, Bjerkan L. Fiber-optic sensor for real-time monitoring of temperature on high voltage (400 kV) power transmission line[J]. Proceedings of SPIE, 7503, 75034M(2009).
[9] Luo J B, Hao Y P, Ye Q et al. Measurement for icing load of transmission lines using fiber Bragg grating sensor[J]. High Voltage Engineering, 40, 405-412(2014).
[11] Wang J J, Li Y Q[J]. Progress on distributed optical fiber sensing technology in OPGW monitoring Study on Optical Communications, 2018, 25-27.
[13] Lü A Q, Li Y Q, Li J. Research on strain and temperature measurement of OPGW based on BOTDR[J]. Proceedings of SPIE, 9044, 90441H(2014).
[14] Zou L, Sezerman O. Long-term monitoring of local stress changes in 67 km installed OPGW cable using BOTDA[J]. Proceedings of SPIE, 9634, 963461(2015).
[15] Li J C, Ge J, Ning N. Running state monitoring of OPGW base on BOTDA. C]∥2009 Yunnan Electric Power Technology Forum. Yunnan: Electric Machine Engineering Institute of Yurnan Province, 99(2009).
Get Citation
Copy Citation Text
Meng Xia, Xiaohui Tang, Ying Wang, Shulin Zhang, Hui Jiang, Yongkang Dong. Comparative Analysis of Strain Monitoring of the Installed Optical Fiber Composite Overhead Ground Wire Using BOTDA/R[J]. Acta Optica Sinica, 2020, 40(15): 1506001
Category: Fiber Optics and Optical Communications
Received: Mar. 31, 2020
Accepted: Apr. 29, 2020
Published Online: Aug. 14, 2020
The Author Email: Dong Yongkang (aldendong@163.com)