Chinese Journal of Lasers, Volume. 45, Issue 4, 404005(2018)

Research on Base Station Layout of Multi-Station and Time-Sharing Measurement by Laser Tracker

Wang Jindong*, Sun Rongkang, Zeng Xiaotao, and Wang Qingjie
Author Affiliations
  • [in Chinese]
  • show less
    Figures & Tables(15)
    Precision detection principle of machine tool by multi-station and tine-sharing measurement by a laser tracker
    Distribution of base stations and measuring points
    Direction vectors between a measuring point and different base stations
    PDOP variation curve of base station P1 which moves 3500 mm along the positive and negative directions of x-axis
    PDOP variation curve of base station P1which moves 3500 mm along the positive and negative directions of z-axis
    PDOP variation curve of base station P1 which moves 900 mm along the positive and negative directions of x-axis
    3D distribution of PDOP at different positions with 2D measuring area
    3D distribution of PDOP at different positions in 3D measuring area
    PDOP distribution on different sections inside the moving area of machine tool. (a) z=800 mm; (b) z=100 mm
    Distribution of base stations
    • Table 1. Average calibration deviations of different base stationsμm

      View table

      Table 1. Average calibration deviations of different base stationsμm

      Base stationΔxΔyΔzM
      P1-2.1-1.2-1.22.7
      P21.72.8-2.94.4
      P3-3.9-3.03.85.8
      P44.62.83.66.5
    • Table 2. Overall calibration deviations and PDOP values of different base stations

      View table

      Table 2. Overall calibration deviations and PDOP values of different base stations

      Base stationM /μmPDOP
      P12.70.405
      P24.40.501
      P35.80.654
      P46.50.755
    • Table 3. PDOP values of different base stations at 1D measuring area

      View table

      Table 3. PDOP values of different base stations at 1D measuring area

      Base stationP1P2P3P4
      PDOP3.7×1074.9×1078.3×108¥
    • Table 4. Overall calibration deviations and their PDOP values at different base stations

      View table

      Table 4. Overall calibration deviations and their PDOP values at different base stations

      Base stationM /mmPDOP
      P12.30.401
      P22.50.401
      P34.20.462
      P45.20.586
    • Table 5. PDOP values of base station P1 at different measuring areas

      View table

      Table 5. PDOP values of base station P1 at different measuring areas

      ItemPDOP
      Number ofmeasurement points20324456
      3D space0.7320.5710.4940.432
      Measuringarea2D plane1.0540.8330.7120.635
      1D line2.8×1081.1×1087.7×1075.8×107
    Tools

    Get Citation

    Copy Citation Text

    Wang Jindong, Sun Rongkang, Zeng Xiaotao, Wang Qingjie. Research on Base Station Layout of Multi-Station and Time-Sharing Measurement by Laser Tracker[J]. Chinese Journal of Lasers, 2018, 45(4): 404005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Measurement and metrology

    Received: Oct. 23, 2017

    Accepted: --

    Published Online: Apr. 13, 2018

    The Author Email: Jindong Wang (wangjindong198205@163.com)

    DOI:10.3788/CJL201845.0404005

    Topics