NUCLEAR TECHNIQUES, Volume. 48, Issue 3, 030601(2025)
Applicability of secondary-developed RELAP5 code for PRS operation analysis under inclined conditions
Fig. 3. Distribution diagram of temperature measuring points in C-type heat exchanger
Fig. 5. Comparison of system parameters with inclination angle of +15° (color online)(a) Pressure, (b) Inlet and outlet temperature of heat exchanger
Fig. 6. Change of key system parameters with inclination angle (a) System pressure, (b) Natural circulation flow, (c) Inlet temperature of heat exchanger, (d) Outlet temperature of heat exchanger
Fig. 7. Boiling phenomenon outside tube of C-type heat exchanger under different inclination angles of -24° (a), -15° (b), 15° (c), 24° (d)
Fig. 8. Change of heat transfer coefficient outside (a) and inner distribution of gas phase fraction (b) of C-type heat exchanger at different inclination angles
|
|
Get Citation
Copy Citation Text
Chengming HAO, Jing ZHAO, Tao WANG, Tiebo LIANG, Yu WANG, Huitian XU, Yan SUN, Qiao YU, Hao ZHANG. Applicability of secondary-developed RELAP5 code for PRS operation analysis under inclined conditions[J]. NUCLEAR TECHNIQUES, 2025, 48(3): 030601
Category: NUCLEAR ENERGY SCIENCE AND ENGINEERING
Received: May. 22, 2023
Accepted: --
Published Online: Apr. 15, 2025
The Author Email: Chengming HAO (676336795@qq.com)