Acta Optica Sinica, Volume. 44, Issue 11, 1132001(2024)
Spatial Resolution Performance Improvement of Pulse-Dilation Framing Camera Using Filtering Technique and GAN
Fig. 2. Analysis of imaging performance. (a) Magnetic field distribution of on-axis; (b) demagnification imaging in half of 20 mm×20 mm area; (c) electron imaging distribution of on-axis; (d) electron imaging distribution at 20 mm off-axis
Fig. 7. Enhancement analysis results of acquired images using different methods. (a) Original images (OI); (b) GAN; (c) Gauss-Laplacian (GL) filtering; (d) homomorphic filtering (HF); (e) GAN and Gauss-Laplacian (G-GL) filtering; (f) GAN and homomorphic filtering (G-HF)
Fig. 8. Quantitative indexes of spatial resolution performance improvement in paraxial and abaxial regions. (a) Overall average gradient of the image; (b) local average gradient in paraxial and abaxial 5 lp/mm regions; (c) average modulation degree for paraxial and abaxial 5 lp/mm regions
Get Citation
Copy Citation Text
Futao Xu, Yanli Bai, Si Zhong, Mingcheng Song. Spatial Resolution Performance Improvement of Pulse-Dilation Framing Camera Using Filtering Technique and GAN[J]. Acta Optica Sinica, 2024, 44(11): 1132001
Category: Ultrafast Optics
Received: Jan. 23, 2024
Accepted: Mar. 4, 2024
Published Online: Jun. 17, 2024
The Author Email: Bai Yanli (bayaly@guet.edu.cn), Zhong Si (zhongsikm@qq.com)
CSTR:32393.14.AOS240551