Chinese Journal of Lasers, Volume. 47, Issue 12, 1204001(2020)
Method for Volume Error Calibration of CMM Based on Inverse-Distance Weighting Algorithm
Fig. 4. Spatial distribution of sampling points (circle is interpolation sample data, and asterisk is accuracy evaluation data)
Fig. 5. IDW interpolation results. (a) Volume error in x direction; (b) volume error in y direction; (c) volume error in z direction
Fig. 6. Difference between volume error obtained by IDW algorithm and volume error measured by laser tracing multi-station measurement system
Fig. 8. Volume error results obtained by trilinear interpolation algorithm. (a) Volume error in x direction; (b) volume error in y direction; (c) volume error in z direction
|
|
|
|
|
Get Citation
Copy Citation Text
Chen Hongfang, Zhang Shuang, Liang Chaowei, Tang Liang, Shi Zhaoyao. Method for Volume Error Calibration of CMM Based on Inverse-Distance Weighting Algorithm[J]. Chinese Journal of Lasers, 2020, 47(12): 1204001
Category: Measurement and metrology
Received: Jun. 12, 2020
Accepted: --
Published Online: Nov. 17, 2020
The Author Email: Hongfang Chen (chf0302@126.com)