High Power Laser and Particle Beams, Volume. 37, Issue 3, 035023(2025)

Influence of isolation element in trigger circuit on synchronization of multiple switches

Jie Wang, Lin Chen*, Yuanwei Feng, Jihao Jiang, Yue Zhao, Hongwei Liu, Wenhui Han, and Liangji Zhou
Author Affiliations
  • Key Laboratory of Pulsed Power, Institute of Fluid Physics, CAEP, Mianyang 621999, China
  • show less
    Figures & Tables(8)
    Equivalent circuit of two switches in different brick triggered by one trigger pulse
    Voltage on trigger electrode of unclosed switch for different isolation resistance
    Voltage on trigger electrode of unclosed switch for different isolation inductance
    LTD cavity which consists of 24 bricks in parallel
    Images of isolation resistor and inductor
    Typical optical signals in experiment
    • Table 1. Voltage amplitude and rise time on trigger electrode of unclosed switch for different isolation inductance or resistance

      View table
      View in Article

      Table 1. Voltage amplitude and rise time on trigger electrode of unclosed switch for different isolation inductance or resistance

      resistance/Ωinductance/μHvoltage amplitude/kVrise time/ns
      two switches keep openingone switch is closedtwo switches keep openingone switch is closed
      150176.089.525.528.8
      300176.0123.527.228.0
      450175.7138.929.831.5
      600175.2146.032.632.6
      1174.5108.812.98.8
      3213.6146.816.613.3
      5236.6176.919.816.7
      7251.4198.522.019.4
    • Table 2. Comparison of gas switches and LTD cavity performances for different isolation element

      View table
      View in Article

      Table 2. Comparison of gas switches and LTD cavity performances for different isolation element

      resistance/Ωinductance/μHwork ratio of switch/%switch jitter/nsrange of time delay/nsload voltage of LTD cavity/kV
      150702.17.681.8
      652.79.081.5
      603.914.281.0
      559.043.777.8
      300701.96.881.5
      652.810.481.1
      603.814.080.6
      559.038.678.7
      550701.86.081.8
      652.06.681.6
      603.313.280.7
      558.033.479.4
      3701.75.881.9
      651.85.681.8
      602.17.281.5
      553.916.480.6
      5701.85.681.9
      651.85.881.8
      601.96.881.4
      552.58.681.2
      7701.85.881.8
      651.95.481.6
      602.07.281.3
      553.214.880.7
    Tools

    Get Citation

    Copy Citation Text

    Jie Wang, Lin Chen, Yuanwei Feng, Jihao Jiang, Yue Zhao, Hongwei Liu, Wenhui Han, Liangji Zhou. Influence of isolation element in trigger circuit on synchronization of multiple switches[J]. High Power Laser and Particle Beams, 2025, 37(3): 035023

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Cutting-edge Interdisciplinary Technologies and Applications of Special Power Supplies

    Received: Oct. 22, 2024

    Accepted: Dec. 26, 2024

    Published Online: Apr. 29, 2025

    The Author Email: Lin Chen (chenlin_mail@163.com)

    DOI:10.11884/HPLPB202537.240371

    Topics