High Power Laser and Particle Beams, Volume. 34, Issue 11, 113001(2022)

Longtime operation of S-band multi-beam relativistic klystron amplifier

Hua Huang, Shifeng Li, Limin Sun, Jie Tan, Peng Wang, Zhenbang Liu, and Qifan Xiang
Author Affiliations
  • Science and Technology on High Power Microwave Laboratory, Institute of Applied Electronics, CAEP, Mianyang, 621900, China
  • show less
    Figures & Tables(10)
    Optimization curves of AJDISK code
    Three dimensions’ simulation diagram of four-cavity RKA
    Output microwave waveform (a) and electron velocity (b) of four-cavity RKA simulation by CST
    Output cavity with water cooling collector
    Output microwave waveforms at different working time. C3-detected waveform, C4-radio frequency waveform
    Last frame waveforms at 20 Hz@10 min. C3-detected waveform,C4-radio frequency waveform
    • Table 1. High frequency parameters of cavities

      View table
      View in Article

      Table 1. High frequency parameters of cavities

      cavitygap width/mm (R/Q)/ Ω Minitialization frequency/GHz
      input cavity14.013.20.8862.875
      idler cavity 1#12.014.20.8662.885
      idler cavity 2#13.515.20.8652.908
      output cavity16.018.10.8412.876
    • Table 2. Voltage effects on electron beam modulation and device efficiency

      View table
      View in Article

      Table 2. Voltage effects on electron beam modulation and device efficiency

      voltage/kVmodulation depthefficiency/%electron reversal (v/c)
      5201.1042.6−0.05
      5301.1040.9−0.08
      5401.1042.90
      5501.0943.60
      5601.0742.0−0.07
      5701.0440.%−0.17
      5800.9939.8−0.03
    • Table 3. Current effects on electron beam modulation and device efficiency

      View table
      View in Article

      Table 3. Current effects on electron beam modulation and device efficiency

      current/Amodulation depth (I1/Io) efficiency/%electron reversal (v/c)
      278×140.9837.00.25
      298×141.0440.0−0.03
      318×141.0842.0−0.04
      338×141.0943.60
      358×141.0942.0−0.13
      378×141.0840.9−0.12
      398×141.0743.5−0.16
    • Table 4. High frequency parameters and drifting tube parameter of four-cavity RKA

      View table
      View in Article

      Table 4. High frequency parameters and drifting tube parameter of four-cavity RKA

      cavitygap width/mmoscillation frequency/GHzaxial position/mm
      input cavity142.880
      idler cavity 1#122.89190
      idler cavity 2#13.52.936180
      output cavity162.879485
    Tools

    Get Citation

    Copy Citation Text

    Hua Huang, Shifeng Li, Limin Sun, Jie Tan, Peng Wang, Zhenbang Liu, Qifan Xiang. Longtime operation of S-band multi-beam relativistic klystron amplifier[J]. High Power Laser and Particle Beams, 2022, 34(11): 113001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: High Power Microwave Technology

    Received: Jun. 12, 2022

    Accepted: --

    Published Online: Oct. 18, 2022

    The Author Email:

    DOI:10.11884/HPLPB202234.220184

    Topics