Acta Optica Sinica, Volume. 26, Issue 5, 697(2006)

Calibration Method with Separation Pattern of a Single-Camera Based on Difference Coordinates

[in Chinese]*, [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    References(4)

    [1] [1] R. Y. Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV camera and lenses[J]. IEEE J. Robotics and Automation, 1987, RA-3(4): 323~344

    [2] [2] Song Dema. A self-calibration technique for active vision systems[J]. IEEE Transactions on Robotics and Automation, 1996, 12(1): 114~120

    [3] [3] S. J. Maybank, O. D. Faugeras. A theory of self-calibration of a moving camera[J]. International J. Computer Vision, 1992, 8(2): 123~151

    [11] [11] Li Weimin, Xing Xiaozheng, Yi Jin et al.. The measurement system for fiber positioning unit of LAMOST[C]. Proc. SPIE, 5492: 584~591

    CLP Journals

    [1] Zhong Hongjun, Yang Mengfei, Lu Xin. Calibration Method of Star Sensor[J]. Acta Optica Sinica, 2010, 30(5): 1343

    [2] Song Yunceng, Chen Wei, Ye Yutang, Liu Juanxiu, Huang Binquan, Guo Tao, Zhao Jin. Sub-Pixel Stitching Method for Large Object with Duplicate Texture of Automatic Visual Inspection[J]. Acta Optica Sinica, 2014, 34(3): 315002

    [3] Li Yingchao, Wang Yongtian, Liu Yue, Li Yanhui. Study on Calibration of Imaging Model and Movement Model of C-Arm Angiography System[J]. Acta Optica Sinica, 2008, 28(10): 1910

    [4] Jiang Guangwen, Chao Zhichao, Fu Sihua, Yu Qifeng. High-Accurate Camera Calibration Technique Based on Controllable Rotation[J]. Acta Optica Sinica, 2010, 30(5): 1308

    [5] Zhang Lingfei, Chen Gang, Ye Dong, Che Rensheng. Cameras Calibration Based on One-Dimensional Reference Object and Improved Evolutionary Strategy[J]. Acta Optica Sinica, 2009, 29(11): 3136

    [6] Dongsheng Yang, Shusheng Bi, Yueri Cai, Chang Yuan. Wide-Area Monocular Plane Measurement Based on Calibration on a Parallel Plane Using Multiple Targets[J]. Acta Optica Sinica, 2017, 37(10): 1015001

    [7] Yuan Guoqin, Ding Yalin, Hui Shouwen, Liu Liguo, Yu Chunfeng. Grouped Approach Algorithm for Mapping Camera Calibration Based on Method of Exact Measuring Angle[J]. Acta Optica Sinica, 2012, 32(1): 112005

    [8] Zhu Jia, Li Xingfei, Xu Yingxin. Camera Calibration Technique Based on Active Vision[J]. Acta Optica Sinica, 2010, 30(5): 1297

    [9] Liu Chang. Two Parallel Planes Calibration for Two-Dimensional Object Vision Measurement[J]. Acta Optica Sinica, 2013, 33(11): 1115004

    [10] Mao Xianfu, Su Xianyu, Liu Yuankun, Chen Wenjing. Analysis on Optical Coordinate Measurement Based on Phase Target[J]. Acta Optica Sinica, 2009, 29(9): 2452

    [11] Huo Ju, Yang Wei, Yang Ming. A Self-Calibration Technique Based on the Geometry Property of the Vanish Point[J]. Acta Optica Sinica, 2010, 30(2): 465

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese]. Calibration Method with Separation Pattern of a Single-Camera Based on Difference Coordinates[J]. Acta Optica Sinica, 2006, 26(5): 697

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: May. 20, 2005

    Accepted: --

    Published Online: Jun. 1, 2006

    The Author Email: (liwm@ustc.edu)

    DOI:

    Topics