Acta Optica Sinica, Volume. 35, Issue 3, 301003(2015)

Fast Radiance Calibration for Ground-Based Large-Aperture Infrared Opto-Electric Equipment

Liu Junchi1,2、*, Li Hongwen1, Wang Jianli1, and Yin Limei1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(21)

    [1] [1] Yang Ciyin, Cao Lihua. Radiation calibration and error analysis for a large-aperture infrared opto-electric system [J]. Infrared and Laser Engineering, 2011, 40(9): 1624-1628.

    [2] [2] Cao Lihua, Li Ning, Yang Ciyin, et al.. Radiance calibration for 3~5 μm infrared detector [J]. Infrared and Laser engineering, 2012, 41(4): 858-864.

    [3] [3] Tang Jia, Cao Xin. Calibration method for radiation characteristics measuring system of test range [J]. Infrared and Laser engineering, 2006, 35(10): 266-270.

    [4] [4] Li Xiansheng, Ren Jianwei, Zhang Liguo, et al.. Research on a radiometric calibration device for a large aperture infrared optoelectric system on spot [J]. Journal of Optoelectronics · Laser, 2006, 17(2): 175-178.

    [5] [5] Yang Ciyin, Zhang Jianping, Cao Lihua. Ground-based spatial object infrared radiation feature measurement technique [J]. Chinese Journal of Scientific Instrument, 2013, 34(2): 304-310.

    [6] [6] Sun Zhiyuan, Li Qingan, Qiao Yanfeng, et al.. Study on raising the precision of infrared temperature measurement system [J]. Chinese Journal of Scientific Instrument, 2006, 27(6): 67-69.

    [10] [10] Liu Yingqi, Liu Xiangyi. Research on technology ground-based infrared radiation feature measurement for space target [J]. Acta Optica Sincia, 2014, 34(5): 0512003.

    [11] [11] L Linhua. Backward Monte Carlo method based on radiation distribution factor [J]. AIAA J Thermophysics Heat Transfer, 2004, 18(1): 151-153.

    [12] [12] Peixin Hu, Qimin Lu, Rong Shu, et al.. An airbone pushbroom hyperspectral imager with wide field of view [J]. Chin Opt Lett, 2005, 3(12): 689-691.

    [13] [13] C Donlon, I S Robinson, M Reynolds, et al.. An infrared sea surface temperature autonomous radiometer (ISAR) for deployment aboard volunteer observing ships (VOS) [J]. J Atm & Oceanic Technol, 2008, 25(1): 93-113.

    [14] [14] L M Vigil, J D Witte, D P Le Van, et al.. Sensor suite for the advanced electro-optical system (AEOS) 3.6-m telescope [C]. SPIE, 1996, 2819: 151-169.

    [15] [15] D Smith, C Mutlow, J Delderfield, et al.. ATSR infrared radiometric calibration and in-orbit performance [J]. Remote Sensing of Environment, 2012, 116(15): 4-16.

    [17] [17] Liu Yingqi. Inversion of space target infrared multi-band temperature distribution [J]. Infrared and Laser Engineering, 2013, 42(3): 556-561.

    [19] [19] Sun Zhiyuan, Chang Songtao, Zhu Wei. Radiation calibration method for infrared system with large aperture and broad dynamic range [J]. Acta Optica Sincia, 2014, 34(7): 0712006.

    [20] [20] Chang Songtao, Zhang Yaoyu, Sun Zhiyuan, et al.. Radiation measurement method for infrared small targets [J]. Acta Optica Sincia, 2014, 34(5): 0504001.

    [21] [21] Liu Zunyang, Shao Li, Wang Yafu, et al.. Influence on afterburning on infrared radiation of solid rocket exhaust plume [J]. Acta Optica Sincia, 2013, 33(6): 0604001.

    CLP Journals

    [1] Xue Li, Zhai Dongsheng, Li Yuqiang, Zhang Labao, Li Zhulian, Kang Lin, Wu Peiheng, Li Ming, Xiong Yaoheng. Ranging Capability Analysis for Laser Ranging System Using Superconducting Nanowire Detectors[J]. Acta Optica Sinica, 2016, 36(3): 304001

    [2] Zhao Yun, Li Manliang, Cui Zhi, Sun Jingang, An Xueguang. Compensation of gray value drift for ground-based MWIR measurement system[J]. Opto-Electronic Engineering, 2018, 45(4): 170535

    [3] Zhang Zhao, Li Xiansheng, Wan Zhi, Sun Jingxu, Liu Hongxing, Liu Zexun, Wang Yamin, Ren Jianwei, Ren Jianyue. Design and Measurement of Radiometric Performance of Ultra-Large Aperture Uniform Light Source[J]. Chinese Journal of Lasers, 2017, 44(4): 410003

    [4] Zhang Zhao, Wan Zhi, Sun Jingxu, Liu Zexun, Ren Jianwei, Ren Jianyue. Development and Calibration of Dual-Waveband Infrared Radiometer for Jones Calibration Method[J]. Acta Optica Sinica, 2016, 36(6): 623002

    [5] LIU Jun-chi, LI Hong-wen, WANG Jian-li, YIN Li-mei, LI Hong-zhuang, ZHAO Jin-yu. Combined radiometric calibration of ground-based large-aperture infrared photoelectric systems[J]. Optics and Precision Engineering, 2017, 25(10): 2541

    [6] Sun Fengying, Mei Haiping, Wu Pengfei, Rao Ruizhong. Research on Whole Sky Spectra Imaging Based on Fiber Spectrometer[J]. Laser & Optoelectronics Progress, 2016, 53(7): 70104

    Tools

    Get Citation

    Copy Citation Text

    Liu Junchi, Li Hongwen, Wang Jianli, Yin Limei. Fast Radiance Calibration for Ground-Based Large-Aperture Infrared Opto-Electric Equipment[J]. Acta Optica Sinica, 2015, 35(3): 301003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Nov. 24, 2014

    Accepted: --

    Published Online: Feb. 10, 2015

    The Author Email: Liu Junchi (liujunchi703@163.com)

    DOI:10.3788/aos201535.0301003

    Topics