Acta Optica Sinica, Volume. 41, Issue 24, 2417001(2021)

Optical Parameter Measurement Method for Mucosal Lesion Recognition in Spatially Resolved Sub-Diffusive Regime

Qi Zhang1, Limin Zhang1,2、*, Jingyi An1, Jing Wang3, chen Chen3, and Feng Gao1,2
Author Affiliations
  • 1School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
  • 2Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin 300072, China
  • 3The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830054, China
  • show less
    Figures & Tables(8)
    Diagrams of light transmission in mucosa, fiber ring subdivision, and photon emission. (a) Diagram of light transmission in mucosa; (b) diagram of fiber ring subdivision; (c) diagram of photon emission
    Training diagram of BPNN model
    Retrieved results of optical parameters obtained by simulation. (a)(d) μa; (b)(e) μ's; (c)(f) γ
    Schematic of measurement system
    Retrieved results of optical parameters obtained by phantom experiment. (a)(d) μa; (b)(e) μ's; (c)(f) γ
    • Table 1. RMSE and rRMSE of optical parameters retrieved by 3D-LUT and BPNN for noise of 0 dB, 20 dB, and 30 dB

      View table

      Table 1. RMSE and rRMSE of optical parameters retrieved by 3D-LUT and BPNN for noise of 0 dB, 20 dB, and 30 dB

      Noise /dBInversemodelRMSE ofμaRMSE of μ'sRMSE ofγrRMSE of μa /%rRMSE ofμ' s /%rRMSE ofγ /%
      03D-LUT0.08000.14620.01522.79091.49440.8201
      BPNN0.03820.05530.00511.09140.72200.2757
      303D-LUT0.08700.14810.01522.83551.56430.8248
      BPNN0.04390.05160.00501.15100.65890.2689
      203D-LUT0.15210.18090.01733.25272.17730.9362
      BPNN0.09180.07370.00671.60311.02520.3645
    • Table 2. Optical parameters of turbid phantoms

      View table

      Table 2. Optical parameters of turbid phantoms

      Experimental No.μa /cm-1μ's /cm-1γ
      107.02.251
      2013.32.251
      31.17.02.251
      41.68.92.011
      51.613.32.251
      61.617.82.011
      72.113.32.251
    • Table 3. RMSE and rRMSE of retrieved optical parameters obtained by 3D-LUT and BPNN

      View table

      Table 3. RMSE and rRMSE of retrieved optical parameters obtained by 3D-LUT and BPNN

      Inverse modelRMSE of μaRMSE of μ'sRMSE of γrRMSE ofμa /%rRMSE ofμ's /%rRMSE ofγ /%
      3D-LUT0.31161.64970.096918.749111.80154.7094
      BPNN0.32271.57870.138720.568211.74906.6988
    Tools

    Get Citation

    Copy Citation Text

    Qi Zhang, Limin Zhang, Jingyi An, Jing Wang, chen Chen, Feng Gao. Optical Parameter Measurement Method for Mucosal Lesion Recognition in Spatially Resolved Sub-Diffusive Regime[J]. Acta Optica Sinica, 2021, 41(24): 2417001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Medical optics and biotechnology

    Received: May. 11, 2021

    Accepted: Jun. 28, 2021

    Published Online: Nov. 30, 2021

    The Author Email: Zhang Limin (zhanglm@tju.edu.cn)

    DOI:10.3788/AOS202141.2417001

    Topics