Spectroscopy and Spectral Analysis, Volume. 41, Issue 10, 3051(2021)

NIR Calibration Transfer Method Based on Minimizing Mean Distribution Discrepancy

Yu-hui ZHAO*, Peng-cheng LU, Yu-bo LUO, and Peng SHAN
Author Affiliations
  • Northeastern University Qinhuangdao Campus, Qinhuangdao 066000, China
  • show less
    Figures & Tables(10)
    Spectral difference between different instruments
    Scatter plots for prediction between instruments M5 and MP5 in SBC, PDS, CCACT, TCR, MSC and MCT
    Scatter plots for prediction between instruments M5 and MP6 in SBC, PDS, CCACT, TCR, MSC and MCT
    Scatter plots for prediction between instruments MP5 and MP6 in SBC, PDS, CCACT, TCR, MSC and MCT
    Scatter plots for prediction between instruments A2 and A1 in SBC, PDS, CCACT, TCR, MSC and MCT
    Scatter plots of prediction results between instruments A3 and A2 by SBC, PDS, CCACT, TCR, MSC and MCT
    Scatter plots of prediction results between instruments A2 and A3 by SBC, PDS, CCACT, TCR, MSC and MCT
    • Table 1. RMSEC and RMSEP of corn datasets with SBC, PDS, TCR, CCACT, MSC and MCT

      View table
      View in Article

      Table 1. RMSEC and RMSEP of corn datasets with SBC, PDS, TCR, CCACT, MSC and MCT

      玉米数据集(水分)m5主仪器-mp5从仪器m5主仪器-mp6从仪器mp5主仪器-mp6从仪器
      迁移方法NRMSECRMSEPRMSECRMSEPRMSECRMSEP
      150.330.320.340.440.210.23
      SBC250.350.250.370.390.190.23
      350.320.270.370.360.190.24
      150.320.26(15a)0.540.43(7a)0.240.35(15a)
      PDS250.340.24(15a)0.600.47(9a)0.220.39(15a)
      350.320.24(15a)0.500.40(5a)0.230.35(15a)
      150.420.240.710.550.430.25
      CCACT250.390.260.600.420.410.25
      350.360.270.540.410.370.25
      TCR01.100.43(6b)1.300.47(4b)0.830.36(10b)
      MSC01.631.791.871.920.920.90
      MCT00.240.200.270.190.160.14
    • Table 2. RMSEC and RMSEP of wheat datasets with SBC, PDS, TCR, CCACT, MSC and MCT

      View table
      View in Article

      Table 2. RMSEC and RMSEP of wheat datasets with SBC, PDS, TCR, CCACT, MSC and MCT

      小麦数据集(蛋白质)A2主仪器-A1从仪器A3主仪器-A2从仪器A2主仪器-A3从仪器
      迁移方法NRMSECRMSEPRMSECRMSEPRMSECRMSEP
      150.640.598.748.660.440.48
      SBC250.580.568.267.080.540.48
      350.520.557.736.000.540.48
      152.202.68(5a)4.193.59(15a)1.811.52(7a)
      PDS251.812.11(15a)3.192.23(3a)1.581.41(15a)
      352.232.39(15a)2.422.07(3a)1.671.35(15a)
      152.672.362.702.253.262.03
      CCACT252.542.042.842.252.942.07
      352.531.202.462.062.751.90
      TCR04.332.42(18b)4.162.12(10b)4.151.92(18b)
      MSC01.631.393.801.251.431.22
      MCT00.380.532.450.630.420.30
    • Table 3. Slope comparison of predicted results of SBC, PDS, TCR, CCACT, MSC and MCT

      View table
      View in Article

      Table 3. Slope comparison of predicted results of SBC, PDS, TCR, CCACT, MSC and MCT

      迁移
      方法
      slope
      m5-mp5m5-mp6mp5-mp6A2-A1A3-A2A2-A3
      SBC0.580.550.681.111.651.12
      PDS1.66-1.842.301.620.561.72
      CCACT1.82-2.693.8422.55164.78163.26
      TCR0.01-0.010.150.912.221.03
      MSC-0.10-0.24-0.010.670.640.69
      MCT1.060.741.020.931.020.99
    Tools

    Get Citation

    Copy Citation Text

    Yu-hui ZHAO, Peng-cheng LU, Yu-bo LUO, Peng SHAN. NIR Calibration Transfer Method Based on Minimizing Mean Distribution Discrepancy[J]. Spectroscopy and Spectral Analysis, 2021, 41(10): 3051