Laser & Optoelectronics Progress, Volume. 60, Issue 16, 1615003(2023)

Binocular Vision Method for Measuring Shaft-in-Hole Assembly Parameters

Lingfei Liu, Daocheng Yuan*, and Lianxin Zhang
Author Affiliations
  • Institute of Machinery Manufacturing Technology, China Academy of Engineering Physics, Mianyang 621000, Sichuan, China
  • show less
    Figures & Tables(17)
    Intersection line of hole plane and shaft. (a) Actual location of the intersection line; (b) relationship between the intersection line and the hole edge
    Overall schematic of the assembly system
    Coordinate relationship of the system
    Imaging projection. (a) Imaging projection process of the outermost bus of the shaft; (b) top view; (c) imaging map
    Calculation process of the center position of the shaft
    Reprojection error analysis
    Calibration area division
    Overall experimental procedure
    Experimental setup
    Original image captured by the two cameras. (a) Image before assembly; (b) image after shaft placement
    Recognition result. (a) Intersection line before calibration; (b) calibration diagram; (c) calibrated intersection line, which is also the final result
    Hole and shaft condition under extreme condition
    Comparison of data before and after calibration. (a) Comparison of measured values; (b) comparison of mean relative errors
    Vertical shot of the experimental equipment and original image
    • Table 1. Measurement results and relative error before error calibration

      View table

      Table 1. Measurement results and relative error before error calibration

      Measurement No.d /mmRelative error /%
      10.300720.28
      20.194922.04
      30.289315.72
      40.25843.36
      50.203418.64
    • Table 2. Measurement results and relative error after error calibration

      View table

      Table 2. Measurement results and relative error after error calibration

      Measurement No.d /mmRelative error /%
      10.26787.12
      20.22759.00
      30.26445.76
      40.25732.92
      50.23257.00
    • Table 3. Measurement results and relative error of extended experiment after calibration

      View table

      Table 3. Measurement results and relative error of extended experiment after calibration

      Measurement No.d /mmRelative error /%
      10.26706.80
      20.26325.28
      30.22898.44
      40.25763.04
      50.24342.64
    Tools

    Get Citation

    Copy Citation Text

    Lingfei Liu, Daocheng Yuan, Lianxin Zhang. Binocular Vision Method for Measuring Shaft-in-Hole Assembly Parameters[J]. Laser & Optoelectronics Progress, 2023, 60(16): 1615003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: Sep. 9, 2022

    Accepted: Oct. 19, 2022

    Published Online: Aug. 18, 2023

    The Author Email: Daocheng Yuan (yuandaocheng@caep.cn)

    DOI:10.3788/LOP222509

    Topics