Acta Photonica Sinica, Volume. 53, Issue 4, 0430002(2024)
Under-sampled Image Quality Measurement Based on Virtual Knife Edge for Next Generation Palomar Spectrograph
[1] HARVEY J, FTACLAS C. Diffraction effects of telescope secondary mirror spiders on various image-quality criteria[J]. Applied Optics, 34, 6337-6349(1995).
[2] FARAH A, GODOY J, VELAZQUEZ F et al. Finite element analysis accuracy of the GTC commissioning instrument structure[C](2003).
[3] CHI Xuefen. OTF measurement of the microscope objectives[J]. Optics and Precision Engineering, 17-19(1990).
[4] MARTIN W C. Determination of optical transfer functions by direct measurement[J]. Photogrammetria, 33, 133-144(1977).
[5] CHEN X H, CHEN Y H, ZHANG L J et al. CCD based digital optical transfer function testing instrument[C](2009).
[6] CHANAN G, TROY M. Strehl ratio and modulation transfer function for segmented mirror telescopes as functions of segment phase error[J]. Applied Optics, 38, 6642-6647(1999).
[7] NUGENT P W, SHAW J A, KEHOE M R et al. Measuring the modulation transfer function of an imaging spectrometer with rooflines of opportunity[J]. Optical Engineering, 49, 84-84(2010).
[8] WANG Z, GLAZOWSKI C E, ZAVISLAN J M. Modulation transfer function measurement of scanning reflectance microscopes[J]. Journal of Biomedical Optics, 12, 051802(2007).
[9] BAREKET N. Second moment of the diffraction point spread function as an image quality criterion[J]. Journal of the Optical Society of America, 69, 1311-1312(1979).
[10] LUXEN M, FÖRSTNER . Characterizing image quality: Blind estimation of the point spread function from a single image[C](2002).
[11] FANG Ming, WANG Cheng, YIN Dali. Optimal Fermi function based PSF calculation and image restoration[J]. Acta Photonica Sinica, 43, 0110001(2014).
[12] ZHANG H S, LI C, DUAN Y X. Modified slanted-edge method to measure the modulation transfer function of camera[J]. Optik-International Journal for Light and Electron Optics, 157, 635-643(2018).
[13] FAN C, LI G D, TAO C. Slant edge method for point spread function estimation[J]. Applied Optics, 54, 4097-4103(2015).
[14] KARCHER A, BEBEK C J, KOLBE W F et al. Measurement of lateral charge diffusion in thick, fully depleted, back-illuminated CCDs[C](2004).
[15] TAKACS P Z, KOTOV I, FRANK J et al. PSF and MTF measurement methods for thick CCD sensor characterization[C](2010).
[16] JIANG H J, HU Z W, XU M M et al. The preliminary design of the next generation Palomar spectrograph for 200-inch Hale telescope[C](2018).
[17] TANG L F, HU Z W, JI H X. Camera optics in the ultraviolet region of the next generation palomar spectrograph[C](2023).
Get Citation
Copy Citation Text
Lifeng TANG, Zhongwen HU, Ru CHEN, Nan ZHOU, Hangxin JI. Under-sampled Image Quality Measurement Based on Virtual Knife Edge for Next Generation Palomar Spectrograph[J]. Acta Photonica Sinica, 2024, 53(4): 0430002
Category:
Received: Oct. 13, 2023
Accepted: Nov. 27, 2023
Published Online: May. 15, 2024
The Author Email: Zhongwen HU (zwhu@niaot.ac.cn)