Infrared and Laser Engineering, Volume. 54, Issue 3, 20240399(2025)

Ultrawide-angle fundus autofluorescence imaging in rats

Ziyang ZHANG1,2, Yunshuai MI1,2, Lin JI1,2, Yun XIAO1,2, Wei XIA3, Yulong LIU4, and Yunhai ZHANG1,2
Author Affiliations
  • 1Division of Life Sciences and Medicine, School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei 230026, China
  • 2Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215000, China
  • 3The First Affiliated Hospital, Soochow University, Suzhou 215006, China
  • 4The Second Affiliated Hospital, Soochow University, Suzhou 215004, China
  • show less
    Figures & Tables(12)
    Optical principle diagram of ultrawide-angle fundus autofluorescence imaging system
    Schematic diagram of field of view calculation
    (a) Schematic diagram of illumination light path; (b) Illumination spot diagram; (c) MTF diagram of illumination; (d) Distortion diagram of illumination system
    Device transmittance parameter curve graph
    Principle diagram of field of view measurement
    Experimental system picture
    Measurement process display picture
    (a) Display diagram of resolution measurement process; (b) Resolution board real image
    (a) Simulated eye real image; (b) Diagram of the relationship between signal-to-noise ratio and the number of superimposed images in simulated eye autofluorescence images
    (a) Image of guiding anesthesia SD rats; (b) Preparation image of SD rat experimental imaging; (c) Single fundus autofluorescence image of SD rats; (c) Images of SD rats overlaid with three fundus autofluorescence images
    • Table 1. Main indicators of galvanometer

      View table
      View in Article

      Table 1. Main indicators of galvanometer

      Device parametersTSH8618CRS 4 kHz
      Scan angle/(°)±20±13
      Mirror size/mm23.5×1612.7×12.7
      Clear aperture/mm19×1012×9.25
    • Table 2. Field of view data

      View table
      View in Article

      Table 2. Field of view data

      NumberHorizontal/(°)Vertical/(°)
      189.7190.29
      291.4192.52
      390.0091.69
      Average90.3891.50
    Tools

    Get Citation

    Copy Citation Text

    Ziyang ZHANG, Yunshuai MI, Lin JI, Yun XIAO, Wei XIA, Yulong LIU, Yunhai ZHANG. Ultrawide-angle fundus autofluorescence imaging in rats[J]. Infrared and Laser Engineering, 2025, 54(3): 20240399

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Biology, medical optics and photonics

    Received: Sep. 10, 2024

    Accepted: --

    Published Online: Apr. 8, 2025

    The Author Email:

    DOI:10.3788/IRLA20240399

    Topics