Acta Optica Sinica, Volume. 31, Issue 6, 617001(2011)

Analysis of Frequency-Modulated Continuous-Wave Lidar Technique for Non-Invasive Blood Glucose Measurement

Xiong Bing*, Wei Wenxiong, and He Jianjun
Author Affiliations
  • [in Chinese]
  • show less
    References(22)

    [1] [1] Omar S.Khalil. Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium[J]. Diabetes Technology & Therapeutics, 2004, 6(5): 660~697

    [2] [2] Valery V. Tuchin. Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues[M]. CRC Press, 2008

    [3] [3] Chen Wenliang, Yang Yue, Xu Kexin et al.. Floating-reference method of noninvasive blood glucose concentration measurement[J]. Nanotechnol. and Precision Eng., 2007, 5(4): 298~301

    [4] [4] K. V. Larin, Massoud Motamedi, T. V. Ashitkov et al.. Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study[J]. Phys. Med. Biol., 2003, 48: 1371~1390

    [5] [5] R. O. Esenaliev, K. V. Larin, I. V. Larina et al.. Noninvasive monitoring of glucose concentration with optical coherence tomography[J]. Opt. Lett., 2001, 26(13): 992~994

    [6] [6] K. V. Larin, T. V. Ashitkov, I. V. Larina et al.. Optical coherence tomography technique for noninvasive blood glucose monitoring: phantom, animal, and human studies[C]. SPIE, 2002, 4619: 157~164

    [7] [7] K. V. Larin, T. V. Ashitkov, I. V. Larina et al.. Optical coherence tomography and noninvasive blood glucose monitoring: a review[C]. SPIE, 2004, 5474: 285~290

    [8] [8] A. J. Hymans, J. Lait. Analysis of a frequency-modulated continuous-wave ranging system[J]. Proc. IEEE, 1960, 107-b: 365~372

    [9] [9] Jesse Zheng. Optical Frequency-Modulated Continuous-Wave(FMCW) Interferometry[M]. Springer Press, 2005. 20~28

    [10] [10] S. R. Chinn, E. A. Swanson. Optical coherence tomography using a frequency-tunable optical source[J]. Opt. Lett., 1997, 22(5): 340~342

    [11] [11] Wu Tong, Ding Zhihua, Wang Kai et al.. Swept source optical coherence tomography based on scanning fiber probe[J]. Acta Optica Sinica, 2009, 29: 37~41

    [12] [12] R. Passy, N. Gisin, J. P. vonder Weid et al.. Experimental and theoretical investigations of coherent OFDR with semiconductor laser sources[J]. J. Lightwave Technol., 1994, 12(9): 1622~1630

    [13] [13] H. C. Hulst. Light Scattering by Small Particles[M]. New York: Dover Press, 1981

    [14] [14] John S. Maier, Scott A. Walker, Sergio Fantini et al.. Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared[J]. Opt. Lett., 1994, 19(24): 2062~2064

    [15] [15] M. Kohl, M. Cope, M. Essenpreis et al.. Influence of glucose concentration on light scattering in tissue-simulating phantoms[J]. Opt. Lett., 1994, 19(24): 2170~2172

    [16] [16] Alan V. Oppenheim, Ronald W. Schafer, John R. Buck. Discrete-Time Signal Processing[M]. 2nd ed., Beijing: Tsinghua University Press, 1999

    [17] [17] Lihong Wang, Steven L. Jacques, Liqiong Zheng. MCML-Monte Carlo modeling of light transport in multi-layered tissues[J]. Computer Methods and Programs in Biomedicine, 1995, 47: 131~146

    [18] [18] Gang Yao, Lihong Wang. Monte Carlo simulation of an optical coherence tomography signal in homogeneous turbid media[J]. Phys. Med. Biol., 1999, 44: 2307~2320

    [19] [19] Luo Qingmin, Gong Hui, Liu Xiande et al.. Simulation and examination of laser propagation in biological tissue[J]. Acta Photonica Sinica, 1995, 24(2): 125~128

    [20] [20] J. M. Schmitt, A. Knuttel, M. Yadlovsky et al.. Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering[J]. Phys. Med. Biol., 1994, 39: 1705~1720

    [21] [21] C. Wai-fung, A. P. Scott, J. W. Ashley. A review of the optical properties of biological tissues [J]. IEEE J. Quant. Electron., 1990, 26(12): 2166~2185

    [22] [22] Christian Matzler. Matlab Functions for Mie Scattering and Absorption[R]. University of Bern,2002

    Tools

    Get Citation

    Copy Citation Text

    Xiong Bing, Wei Wenxiong, He Jianjun. Analysis of Frequency-Modulated Continuous-Wave Lidar Technique for Non-Invasive Blood Glucose Measurement[J]. Acta Optica Sinica, 2011, 31(6): 617001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Medical optics and biotechnology

    Received: Dec. 10, 2010

    Accepted: --

    Published Online: May. 31, 2011

    The Author Email: Bing Xiong (xiongbing@coer.zju.edu.cn)

    DOI:10.3788/aos201131.0617001

    Topics