Chinese Optics, Volume. 16, Issue 2, 434(2023)

Theoretical investigation on super-resolution refractive index measurement with parity detection

Qiang WANG, Qian-qian WANG, Zhen WANG, and Li-li HAO*
Author Affiliations
  • School of Physics and Electronic Engineering, Northeast Petroleum University, Daqing 163318, China
  • show less
    References(24)

    [1] EL-KASHEF H. Study of the refractive properties of laser dye solvents: toluene, carbon disulphide, chloroform, and benzene[J]. Optical Materials, 20, 81-86(2002).

    [2] [2] PEI N Q. Optimization experiment on seawater’s refractive index measurement system[D]. Wuhan: Huazhong University of Science Technology, 2017. (in Chinese)

    [3] INDRASARI W, UMIATIN U, FITRIANI N. Measurement system development of refractive index, salinity and magnetic field parameters on liquid waste polluted water[J]. Journal of Physics:Conference Series, 1869, 012201(2021).

    [4] CONTEDUCA D, BARTH I, PITRUZZELLO G, et al. Dielectric nanohole array metasurface for high-resolution near-field sensing and imaging[J]. Nature Communications, 12, 3293(2021).

    [5] [5] ZHANG J. Measurement of crystal refractive index based on Michelson interferometry[D]. Ji′nan: Shong University, 2009. (in Chinese)

    [6] HU Y, LV J H, HAO Q. Refractive index measurement of glass with arbitrary shape based on Brewster’s law and a focusing probe beam[J]. Sensors, 21, 2421(2021).

    [7] FU X L, FENG J, FAN X H, et al. Optimization design and test of a high-precision measuring device of liquid refractive index based on the method of minimum deviation angle[J]. Chinese Optics, 15, 789-796(2022).

    [8] LI G Q, CEN X, SU J, et al. Fabry-Perot cavity enhanced Prism for highly sensitive refractive index measurement of Water[J]. Optik, 245, 167688(2021).

    [9] WANG W SH, XU B, ZHANG J. The principle formula error of measuring the refractive index by the method of minimum deviation angle and the method of V-prism[J]. Journal of Changchun Institute of Optics and Fine Mechanics, 18, 5-10(1995).

    [10] IDRIS N, MASWATI, YUSIBANI E. The effect of the thickness of the glass plate of a hollow prism on the accuracy of measuring the refractive index of edible oil[J]. Optik, 217, 164834(2020).

    [11] LIU J Q, ZHENG Y Q, YANG X M, et al. Measurement of refractive index of potassium chloride and phenolphthalein by wedge interferometry[J]. The Wind of Science and Technology, 105(2020).

    [12] DU D R, LI Y, SHANG CH L, et al. Measurement of liquid refractive index by Michelson interferometer[J]. Physical Experiment of College, 32, 43-45(2019).

    [13] SANJID M A, CHAUDHARY K P. Measurement of refractive index of liquids using length standards traceable to SI unit[J]. MAPAN, 31, 89-95(2016).

    [14] STONE J, EGAN P, GERTY D, et al. Picometer metrology for precise measurement of refractive index, pressure, and temperature[J]. NCSLI Measure, 8, 67-73(2013).

    [15] ZHANG L Y, GU J G. Discussion on relation between Interference and refractive index of Newtonian rings based on Mathematica[J]. Guangxi Physics, 42, 28-32(2021).

    [16] WEI F H, ZHANG X J, TANG SH F. Design and analysis of photonic crystal fiber refractive index sensor based on surface Plasmon resonance[J]. Semiconductor Optoelectronics, 41, 35-38,43(2020).

    [17] ZHANG H Y, ZHAO H H, XU X Y, et al. Measurement of water refractive index by dispersive interferometry[J]. Laser & Infrared, 50, 781-788(2020).

    [18] CHOI H J, LIM H H, MOON H S, et al. Measurement of refractive index and thickness of transparent plate by dual-wavelength interference[J]. Optics Express, 18, 9429-9434(2010).

    [19] BOTO A N, KOK P, ABRAMS D S, et al. Quantum interferometric optical lithography: exploiting entanglement to beat the diffraction limit[J]. Physical Review Letters, 85, 2733-2736(2000).

    [20] ZHANG X CH, PAN R, HAN J Y, et al. Recent progress and prospects of topological quantum material-based photodetectors[J]. Chinese Optics, 14, 43-65(2021).

    [21] BOLLINGER J J, ITANO W M, WINELAND D J, et al. Optimal frequency measurements with maximally correlated states[J]. Physical Review A, 54, R4649-R4652(1996).

    [22] GERRY C C. Heisenberg-limit interferometry with four-wave mixers operating in a nonlinear regime[J]. Physical Review A, 61, 043811(2000).

    [23] DISTANTE E, JEŽEK M, ANDERSEN U L. Deterministic superresolution with coherent states at the shot noise limit[J]. Physical Review Letters, 111, 033603(2013).

    [24] ANISIMOV P M, RATERMAN G M, CHIRUVELLI A, et al. Quantum metrology with two-mode squeezed vacuum: parity detection beats the Heisenberg limit[J]. Physical Review Letters, 104, 103602(2010).

    Tools

    Get Citation

    Copy Citation Text

    Qiang WANG, Qian-qian WANG, Zhen WANG, Li-li HAO. Theoretical investigation on super-resolution refractive index measurement with parity detection[J]. Chinese Optics, 2023, 16(2): 434

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Original Article

    Received: Jun. 10, 2022

    Accepted: --

    Published Online: Apr. 4, 2023

    The Author Email: Li-li HAO (haolili0820@126.com)

    DOI:10.37188/CO.2022-0119

    Topics