Acta Optica Sinica, Volume. 37, Issue 12, 1234001(2017)

Development of X-Ray Streak Camera with Large Dynamic Range and High Temporal-Spatial Resolution

Li Gu1,2, Fangke Zong1,2, Xiang Li3, Junlan Zhou1, Qinlao Yang1、*, and Baoping Guo1
Author Affiliations
  • 1 Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
  • 2 College of Information Engineering, Shenzhen University, Shenzhen, Guangdong 518060, China
  • 3 Institute for Advanced Study, Shenzhen University, Shenzhen, Guangdong 518060, China
  • show less
    Figures & Tables(15)
    Electrode design of streak image converter tube
    Axis potential distribution of streak image converter tube
    Newly developed streak image converter tube
    Schematic of static testing for streak image converter tube
    Static spatial resolution image of streak image converter tube
    (a) Schematic and (b) photo of dynamic testing for streak camera
    Dynamic spatial resolution images of streak camera
    Dynamic temporal resolution images of streak camera
    Sweep speed images of streak camera. (a) S1; (b) S2; (c) S3; (d) S4
    Dynamic range image of streak camera
    • Table 1. Voltage and structure parameters of streak image converter tube

      View table

      Table 1. Voltage and structure parameters of streak image converter tube

      Electrode voltage /kVLength /mmMagnificationDeflection sensitivity /(mm·kV-1)
      P/CMF1A1F2A2P/S
      010.426.1510.421.8912124841.6060.71
    • Table 2. Static spatial resolution data of streak image converter tube

      View table

      Table 2. Static spatial resolution data of streak image converter tube

      Resolution /(lp·mm-1)Distance /mmCTF
      221.20.206
      184.70.305
      128.20.653
      1011.70.753
    • Table 3. Dynamic spatial resolution data of streak camera

      View table

      Table 3. Dynamic spatial resolution data of streak camera

      Resolution /(lp·mm-1)Distance /mmCTF
      201.20.162
      164.70.253
      128.20.536
      1011.70.620
    • Table 4. Dynamic temporal resolution data of streak camera

      View table

      Table 4. Dynamic temporal resolution data of streak camera

      Optical path difference /mmTime interval /psInterval /pixelWidth 1 /pixelWidth 2 /pixelAverage width /pixelTime resolution /ps
      361201255.505.005.255.04
    • Table 5. Sweep speed data of streak camera

      View table

      Table 5. Sweep speed data of streak camera

      RangeEtalon distance /mm(ps)Average interval /pixelStandard deviation /pixelSweep speed nonlinearity /%Sweep speed /(mm·ns-1)
      S135(233)252.35.82.311.2
      S275(500)262.74.71.85.5
      S3150(1000)257.76.82.62.7
      S4150(1000)140.92.51.81.5
    Tools

    Get Citation

    Copy Citation Text

    Li Gu, Fangke Zong, Xiang Li, Junlan Zhou, Qinlao Yang, Baoping Guo. Development of X-Ray Streak Camera with Large Dynamic Range and High Temporal-Spatial Resolution[J]. Acta Optica Sinica, 2017, 37(12): 1234001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: X-Ray Optics

    Received: Jul. 12, 2017

    Accepted: --

    Published Online: Sep. 6, 2018

    The Author Email: Yang Qinlao (qlyang@szu.edu.cn)

    DOI:10.3788/AOS201737.1234001

    Topics