    Figures & Tables(21)
    Spatial illumination uniformity evaluation system
    Scheme structures of plant growth shelves. (a) Scheme I; (b) scheme II; (c) scheme III
    Local section of plant growth shelf in scheme I and related parameters
    Local section of plant growth shelf in scheme II and related parameters
    Local section of plant growth shelf in scheme III and related parameters
    SN corresponding to each level of each factor in scheme I. (a) Illumination uniformity of horizontal plane; (b) illumination uniformity of vertical plane; (c) color-mixed uniformity of horizontal plane; (d) color-mixed uniformity of vertical plane
    SN corresponding to each level of each factor in scheme II. (a) Illumination uniformity of horizontal plane; (b) illumination uniformity of vertical plane; (c) color-mixed uniformity of horizontal plane; (d) color-mixed uniformity of vertical plane
    SN corresponding to each level of each factor in scheme III. (a) Illumination uniformity of horizontal plane; (b) illumination uniformity of vertical plane; (c) color-mixed uniformity of horizontal plane; (d) color-mixed uniformity of vertical plane
    Variation of each attribute with factor A. (a) Illumination uniformity and color-mixed uniformity of horizontal plane;(b) illumination uniformity and color-mixed uniformity of vertical plane
    Variation of each attribute with factor C. (a) Illumination uniformity and color-mixed uniformity ofhorizontal plane; (b) illumination uniformity and color-mixed uniformity of vertical plane
    Optimal result of plant growth shelf. (a) Illumination map of horizontal plane; (b) chromaticity map of horizontal plane; (c) full color-mixed map of horizontal plane; (d) illumination map of vertical plane; (e) chromaticity map of vertical plane; (f) full color-mixed map of vertical plane
    Plant growth model
    Illumination uniformity and color-mixed uniformity at each plant height. (a) Illumination uniformity and color-mixed uniformity of planting plane; (b) illumination uniformity and color-mixed uniformity of plant top plane; (c) illumination uniformity and color-mixed uniformity of plant side plane
    Array LED structure and uniformity properties. (a) Array LED structure; (b) illuminance uniformity of reference surface at each plant height; (c) illuminance distribution of vertical reference plane
    • Table 1. Influence factors of plant growth shelf in scheme I and its control levels

      View table

      Table 1. Influence factors of plant growth shelf in scheme I and its control levels

      CodeFactorNumber oflevelsValue
      123
      AH3300 mm400 mm500 mm
      BL3150 mm200 mm250 mm
      Ca30.250.500.75
      Dl310 mm15 mm20 mm
    • Table 2. Influence factors of plant growth shelf in scheme II and its control levels

      View table

      Table 2. Influence factors of plant growth shelf in scheme II and its control levels

      CodeFactorNumber oflevelsValue
      123
      AH3300 mm400 mm500 mm
      BL3150 mm200 mm250 mm
      Ch320 mm30 mm40 mm
      Dl310 mm15 mm20 mm
    • Table 3. Influence factors of plant growth shelf in scheme III and its control levels

      View table

      Table 3. Influence factors of plant growth shelf in scheme III and its control levels

      CodeFactorNumber of levelsValue
      123
      AH3300 mm400 mm500 mm
      BL3150 mm200 mm250 mm
      Ca30.250.500.75
      Dh320 mm30 mm40 mm
      El310 mm15 mm20 mm
    • Table 4. L9(34) orthogonal experimental design in scheme I

      View table

      Table 4. L9(34) orthogonal experimental design in scheme I

      Experiment No.LevelIlluminationuniformityof horizontalplane /%Color-mixeduniformityof horizontalplane /%Illuminationuniformityof verticalplane/%Color-mixeduniformityof verticalplane /%
      ABCD
      1111192.5788.5582.0887.35
      2122283.7183.9471.5577.58
      3133391.7877.8874.9886.16
      4212387.8387.3872.0789.11
      5223189.0972.8468.4284.86
      6231291.7281.5383.9881.69
      7313292.5981.2168.8190.00
      8321393.5689.8883.3788.36
      9332188.7890.0059.7385.67
    • Table 5. L9(34) orthogonal experimental design in scheme II

      View table

      Table 5. L9(34) orthogonal experimental design in scheme II

      Experiment No.LevelIlluminationuniformityof horizontalplane /%Color-mixeduniformityof horizontalplane /%Illuminationuniformityof verticalplane /%Color-mixeduniformityof verticalplane /%
      ABCD
      1111188.2776.6468.1787.84
      2122292.9682.9871.8283.94
      3133391.5085.9778.7274.90
      4212391.3090.0071.3583.83
      5223191.7678.6170.3684.55
      6231293.0678.6672.2884.59
      7313293.2077.4064.5390.00
      8321392.8086.0571.8081.73
      9332194.2170.4465.0688.75
    • Table 6. L18(37) orthogonal experimental design in scheme III

      View table

      Table 6. L18(37) orthogonal experimental design in scheme III

      ExperimentNo.LevelIlluminationuniformityof horizontalplane /%Color-mixeduniformityof horizontalplane /%Illuminationuniformityof verticalplane /%Color-mixeduniformityof verticalplane /%
      ABCDE
      11111182.5985.6667.9075.90
      21222273.3782.0263.7782.48
      31333364.8876.4375.9770.73
      42112282.1885.8666.7685.32
      52223382.0172.4164.7175.36
      62331169.4868.6052.8876.51
      73121381.2581.5564.2686.62
      83232177.8580.0245.9981.97
      93313281.1378.5463.9188.39
      101133283.7090.0075.6988.69
      111211374.8076.1067.5078.07
      121322169.1482.3159.7585.00
      132123180.0776.2551.0290.00
      142231279.8676.7763.0779.62
      152312380.2979.8665.9975.40
      163132383.9676.9062.7681.96
      173213179.3273.3848.3282.72
      183321271.1566.5754.2480.35
    • Table 7. Contribution of each factor to illumination uniformity and mixed-color uniformity

      View table

      Table 7. Contribution of each factor to illumination uniformity and mixed-color uniformity

      InfluencefactorContribution toilluminationuniformity ofhorizontal plane /%Contribution toilluminationuniformity ofvertical plane /%Contribution tocolor-mixeduniformity ofhorizontal plane /%Contribution tocolor-mixeduniformity ofvertical plane /%
      A84.560511.411222.416924.5248
      B1.50931.43747.641428.1085
      C11.712171.791166.248121.2896
      D2.218115.36033.693626.0771
    Tools

    Get Citation

    Copy Citation Text

    Feiyu Jiao, Shangsheng Wen, Bingxu Ma, Bo Zhang, Xinyu Jiang, Yunle Lu, Weizhao Huang, Qibao Wu. Design of Stereo LED Plant Light Source System with High Spatial Illumination Uniformity[J]. Acta Optica Sinica, 2020, 40(18): 1822002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Apr. 2, 2020

    Accepted: Jun. 11, 2020

    Published Online: Aug. 27, 2020

    The Author Email: Jiao Feiyu (shshwen@scut.edu), Wen Shangsheng (shshwen@scut.edu)

    DOI:10.3788/AOS202040.1822002

    Topics