Chinese Journal of Lasers, Volume. 47, Issue 5, 0506003(2020)

Analysis of Factors Affecting Accuracy of Brillouin Frequency Shift Extraction Based on Similarity Matching

Lijuan Zhao1, Heqing Wang1, Zhiniu Xu2、*, and Xiaoxia Che1
Author Affiliations
  • 1Department of Electronic and Communication Engineering, North China Electric Power University, Baoding, Hebei 0 71003, China
  • 2Department of Electrical Engineering, North China Electric Power University, Baoding, Hebei 0 71003, China
  • show less
    Figures & Tables(14)
    Brillouin gain spectrum
    Schematic of similarity matching method
    Measured Brillouin spectrum and calculated frequency shift results. (a) Brillouin spectra for calculation; (b) BFS along the fiber by the model method when the average superposition is 218; (c) difference in calculated BFS between the two methods when the average superposition is 214
    Influence of linewidth on frequency shift extractionaccuracy under different sampling point number of SDS
    Influence of linewidth of SDS on algorithm accuracy under different SNR of SDS
    Influence of SNR of SRS on frequency shift extraction accuracy under different SNR of SDS
    Influence of SNR of SDS on frequency shift extraction accuracy under different SNR of SRS
    Influence of sweeping step of SRS on frequency shift extraction accuracy under different SNR of SDS
    Influence of sweeping step of SDS on frequency shift extraction accuracy under different SNR of SDS.(a) Error of BFS; (b) normalized error of BFS
    Influence of sweeping range of SRS on frequency shift extraction accuracy under different SNR of SDS. (a) Error of BFS; (b) algorithm runtime
    Influence of sweeping range of SDS on frequency shift extraction accuracy. (a) SDS symmetrical about vB; (b) SDS not symmetrical about vB
    • Table 1. Fitting results of influence of linewidth on frequency shift extraction accuracy

      View table

      Table 1. Fitting results of influence of linewidth on frequency shift extraction accuracy

      Number of samplingpoints of SDSpSSERMSE
      30.037950.059250.06606
      50.026960.004890.0187
      100.020030.002240.0126
      150.017170.000830.0077
      200.015280.000690.007
      250.014020.000540.0062
    • Table 2. Fitting results of influence of SNR of SRS on frequency shift extraction accuracy

      View table

      Table 2. Fitting results of influence of SNR of SRS on frequency shift extraction accuracy

      SNR ofSDS /dBabcSSERMSE
      00.2625-0.00755.0130.00040.0206
      53.845-0.11972.7780.00010.1261
      105.6613-0.1241.50890.00030.0061
      153.1407-0.08670.78620.00020.0005
      204.5399-0.10540.47170.00010.0026
    • Table 3. Fitting results of influence of SNR of SDS on frequency shift extraction accuracy

      View table

      Table 3. Fitting results of influence of SNR of SDS on frequency shift extraction accuracy

      SNR ofSRS /dBabcSSERMSE
      305.001-0.12690.2540.00130.0183
      354.983-0.12840.19580.00040.0107
      405.116-0.13270.18150.00020.0082
    Tools

    Get Citation

    Copy Citation Text

    Lijuan Zhao, Heqing Wang, Zhiniu Xu, Xiaoxia Che. Analysis of Factors Affecting Accuracy of Brillouin Frequency Shift Extraction Based on Similarity Matching[J]. Chinese Journal of Lasers, 2020, 47(5): 0506003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: fiber optics and optical communications

    Received: Nov. 25, 2019

    Accepted: Jan. 19, 2020

    Published Online: May. 12, 2020

    The Author Email: Zhiniu Xu (wzcnjxx@sohu.com)

    DOI:10.3788/CJL202047.0506003