Laser & Infrared, Volume. 54, Issue 10, 1607(2024)
Modulation and demodulation method of functional near-infrared spectroscopy system with high sampling rate
[1] [1] Ferrari M, Quaresima V. A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application[J]. Neuroimage, 2012, 63(2): 921-935.
[2] [2] Chiarelli AM, Maclin EL, Low KA, et al. Combining energy and Laplacian regularization to accurately retrieve the depth of brain activity of diffuse optical tomographic data[J]. Biomed Opt, 2016, 21(3): 36008.
[3] [3] Gratton Gabriele, Chiarelli Antonio M, Fabiani Monica. From brain to blood vessels and back: a noninvasive optical imaging approach[J]. Neurophotonics, 2017, 4(3): 031208.
[4] [4] X Huang, J Tang, J Luo, et al. Wearable functional near-infrared spectroscopy (fNIRS) system for obstructive sleep apnea assessment[J]. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2023, 31: 1837-1846.
[9] [9] Ji H, Xu Z, Wang M, et al. A flexible optoelectronic device for continuous cerebral blood flow monitoring[J]. Biosensors (Basel).2022;12(11): 944.
[10] [10] G Wang, et al. The Diagnosis of major depressive disorder through wearable fNIRS by using wavelet transform and parallel-CNN feature fusion[J]. IEEE Transactions on Instrumentation and Measurement, 2023, 72: 1-11.
[11] [11] Arivudaiyanambi J, Mohan S, Cherian SM, et al. Design of a wearable four-channel near-infrared spectroscopy system for the measurement of brain hemodynamic responses[J]. Biomed Tech (Berl).2021, 66(1): 1-9.
[12] [12] Kiguchi M, Atsumori H, Fukasaku I, et al. Note: wearable near-infrared spectroscopy imager for haired region[J]. Rev Sci Instrum, 2012;83(5): 056101.
[13] [13] Zhao H, Cooper RJ. Review of recent progress toward a fiberless, whole-scalp diffuse optical tomography system[J]. Neurophotonics, 2018;5(1): 011012.
[14] [14] Chiarelli A M, Zappasodi F, Di Pompeo F, et al. Simultaneous functional near-infrared spectroscopy and electroencephalography for monitoring of human brain activity and oxygenation: a review[J]. Neurophotonics, 2017;4(4): 041411.
[15] [15] Keles H O, Cengiz C, Demiral I, et al. High density optical neuroimaging predicts surgeons's subjective experience and skill levels[J]. PLoS One, 2021;16(2): e0247117.
[16] [16] Peters S, Lim S B, Louie D R, et al. Passive, yet not inactive: robotic exoskeleton walking increases cortical activation dependent on task[J]. J Neuroeng Rehabil, 2020;17(1): 107.
[18] [18] Cheng J, Xu Y, Wu L, Wang G. A Digital lock-in amplifier for use at temperatures of up to 200 ℃[J]. Sensors (Basel), 2016, 16(11): 1899.
[19] [19] He D, Morgan S P, Trachanis D, et al. A single-chip CMOS pulse oximeter with on-chip lock-in detection[J]. Sensors (Basel), 2015, 15(7): 17076-17088.
[20] [20] Macias-Bobadilla G, Rodrguez-Resndiz J, Mota-Valtierra G, et al. Dual-phase lock-in amplifier based on FPGA for low-frequencies experiments[J]. Sensors (Basel), 2016, 16(3): 379.
Get Citation
Copy Citation Text
LIU Ming-han, LI Chun-guang, ZHAO Yong-jian, WANG Xin-ying, WANG Jian-wei, YAN Wei. Modulation and demodulation method of functional near-infrared spectroscopy system with high sampling rate[J]. Laser & Infrared, 2024, 54(10): 1607
Category:
Received: Dec. 14, 2023
Accepted: Apr. 23, 2025
Published Online: Apr. 23, 2025
The Author Email: LI Chun-guang (lichunguang@suda.edu.cn)