Journal of Tongji University(Medical Science), Volume. 46, Issue 3, 391(2025)

Application advances of new methods for thrombus screening and rapid detection

ZHOU Zhenyu1, ZHANG Qiqiang2, JIA Congcong2, DI Xuemei2, YU Meixiang2, CAO Yan3, and ZHANG Hai2、*
Author Affiliations
  • 1School of Medicine, Shanghai University, Shanghai 200444, China
  • 2Department of Pharmacy, Obstetrics and Gynecology Hospital, Tongji University, Shanghai 201204, China
  • 3School of Pharmacy, Naval Medical University, Shanghai 200433, China
  • show less
    References(36)

    [1] [1] MAO Y, REN J, YANG L F. Advances of nanomedicine in treatment of atherosclerosis and thrombosis[J]. Environ Res, 2023, 238(Pt 2): 116637.

    [2] [2] FREUND Y, ROUSSEAU A, GUYOT-ROUSSEAU F, et al. PERC rule to exclude the diagnosis of pulmonary embolism in emergency low-risk patients: study protocol for the PROPER randomized controlled study[J]. Trials, 2015, 16(1): 537.

    [4] [4] GHASEMI M, OH J, JEONG S, et al. Fabry-perot interferometric fiber-optic sensor for rapid and accurate thrombus detection[J]. Biosensors, 2023, 13(8): 817.

    [5] [5] QIAO R R, HUANG X M, QIN Y, et al. Recent advances in molecular imaging of atherosclerotic plaques and thrombosis[J]. Nanoscale, 2020, 12(15): 8040-8064.

    [6] [6] LUPPA P B, MLLER C, SCHLICHTIGER A, et al. Point-of-care testing (POCT): current techniques and future perspectives[J]. Trac Trends Anal Chem, 2011, 30(6): 887-898.

    [7] [7] BULLER H R, CATE-HOEK A J, HOSE A W. et al. Safely ruling out deep venous thrombosis in primary care[J]. Ann Intern Med, 2009, 150(4): 229-35.

    [8] [8] PRICE C P, FAY M, HOPSTAKEN R M. Point-of-care testing for D-dimer in the diagnosis of venous thromboembolism in primary care: a narrative review[J]. Cardiol Ther, 2021, 10(1): 27-40.

    [9] [9] TEN CATE-HOEK A J, TOLL D B, BLLER H R, et al. Cost-effectiveness of ruling out deep venous thrombosis in primary care versus care as usual[J]. J Thromb Haemost, 2009, 7(12): 2042-2049.

    [10] [10] GROSSE S D, NELSON R E, NYARKO K A, et al. The economic burden of incident venous thromboembolism in the United States: a review of estimated attributable healthcare costs[J]. Thromb Res, 2016, 137: 3-10.

    [11] [11] ZHOU J R, QI Q Q, WANG C, et al. Surface plasmon resonance (SPR) biosensors for food allergen detection in food matrices[J]. Biosens Bioelectron, 2019, 142: 111449.

    [12] [12] HU X E, LV D Y, QI M Y, et al. A new surface plasmon resonance-based immunoassay for rapid and sensitive quantification of D-dimer in human plasma for thrombus screening[J]. J Chromatogr B, 2024, 1238: 124102.

    [13] [13] MOBERG A, LAGER A, HMLINEN M D, et al. Increased sensitivity of SPR assays in plasma through efficient parallel assay optimization[J]. J Pharm Biomed Anal, 2013, 78: 224-232.

    [14] [14] BHAT M, ABUZIED Y, FAGIH Z, et al. Efficacy of point-of-care for INR testing compared to standard laboratory methods at a tertiary care hospital in Saudi Arabia[J]. Glob J Qual Saf Healthc, 2020, 3(3): 98-104.

    [15] [15] LAURENCE C O, GIALAMAS A, BUBNER T, et al. Patient satisfaction with point-of-care testing in general practice[J]. Br J Gen Pract, 2010, 60(572): e98-104.

    [16] [16] ARAJO A C O, DOMINGUES R B, VAN BELLEN B. Comparison between the conventional method and a portable device for determination of INR[J]. J Vasc Bras, 2014, 13(2): 88-93.

    [17] [17] LEITO C, PEREIRA S O, MARQUES C, et al. Cost-effective fiber optic solutions for biosensing[J]. Biosensors, 2022, 12(8): 575.

    [18] [18] DZIUDA . Fiber-optic sensors for monitoring patient physiological parameters: a review of applicable technologies and relevance to use during magnetic resonance imaging procedures[J]. J Biomed Opt, 2015, 20(1): 010901.

    [19] [19] NEDOMA J, KEPAK S, FAJKUS M, et al. Magnetic resonance imaging compatible non-invasive fibre-optic sensors based on the Bragg gratings and interferometers in the application of monitoring heart and respiration rate of the human body: a comparative study[J]. Sensors, 2018, 18(11): 3713.

    [20] [20] Ultrasound guidelines: emergency, point-of-care, and clinical ultrasound guidelines in medicine[J]. Ann Emerg Med, 2023, 82(3): e115-e155.

    [21] [21] POMERO F, DENTALI F, BORRETTA V, et al. Accuracy of emergency physician-performed ultrasonography in the diagnosis of deep-vein thrombosis: a systematic review and meta-analysis[J]. Thromb Haemost, 2013, 109(1): 137-145.

    [22] [22] ZHANG P, QU Y L, TU J, et al. Applicability of bedside ultrasonography for the diagnosis of deep venous thrombosis in patients with COVID-19 and treatment with low molecular weight heparin[J]. J Clin Ultrasound, 2020, 48(9): 522-526.

    [23] [23] ALHARTHY A, FAQIHI F, ABUHAMDAH M, et al. Prospective longitudinal evaluation of point-of-care lung ultrasound in critically ill patients with severe COVID-19 pneumonia[J]. J Ultrasound Med, 2021, 40(3): 443-456.

    [24] [24] ESTRELLA Y, BRONZO A, FEY L, et al. Point-of-care ultrasound: impact on emergency department length of stay for suspected lower extremity DVT[J]. Emerg Radiol, 2023, 30(2): 203-207.

    [25] [25] ADHIKARI S, ZEGER W, THOM C, et al. Isolated deep venous thrombosis: implications for 2-point compression ultrasonography of the lower extremity[J]. Ann Emerg Med, 2015, 66(3): 262-266.

    [26] [26] CANAKCI M E, ACAR N, BILGIN M, et al. Diagnostic value of point-of-care ultrasound in deep vein thrombosis in the emergency department[J]. J Clin Ultrasound, 2020, 48(9): 527-531.

    [27] [27] LEE J H, LEE S H, YUN S J. Comparison of 2-point and 3-point point-of-care ultrasound techniques for deep vein thrombosis at the emergency department: a metaanalysis[J]. Medicine (Baltimore), 2019, 98(22): e15791.

    [28] [28] FRANKEL H L, KIRKPATRICK A W, ELBARBARY M, et al. Guidelines for the appropriate use of bedside general and cardiac ultrasonography in the evaluation of critically ill patients: part I[J]. Crit Care Med, 2015, 43(11): 2479-2502.

    [29] [29] BLAIVAS M, LAMBERT M J, HARWOOD R A, et al. Lower-extremity Doppler for deep venous thrombosis: can emergency physicians be accurate and fast?[J]. Acad Emerg Med, 2000, 7(2): 120-126.

    [30] [30] GRAY B P, KELLY L, STEEN-BURRELL K A, et al. Rapid molecular imaging of active thrombiin vivousing aptamer-antidote probes[J]. Mol Ther Nucleic Acids, 2023, 31: 440-451.

    [31] [31] NIMJEE S M, WHITE R R, BECKER R C, et al. Aptamers as therapeutics[J]. Annu Rev Pharmacol Toxicol, 2017, 57: 61-79.

    [32] [32] ZHANG W, LI M M, WANG X, et al. Precision navigation of venous thrombosis guided by viscosity-activatable near-infrared fluorescence[J]. Anal Chem, 2023, 95(4): 2382-2389.

    [33] [33] DYR J E, STIKAROVA J, SUTTNAR J, et al. Measurable amount of active thrombin is bound to circulating D-dimers. is there any impact on diagnosis and pathophysiology of thrombosis?[J]. Blood, 2016, 128(22): 2570.

    [34] [34] ALONS I M E, JELLEMA K, WERMER M J H, et al. D-dimer for the exclusion of cerebral venous thrombosis: a meta-analysis of low risk patients with isolated headache[J]. BMC Neurol, 2015, 15(1): 118.

    [35] [35] GOTTLIEB I, PINHEIRO A, BRINKER J A, et al. Diagnostic accuracy of arterial phase 64-slice multidetector CT angiography for left atrial appendage thrombus in patients undergoing atrial fibrillation ablation[J]. J Cardiovasc Electrophys, 2008, 19(3): 247-251.

    [36] [36] MARTINEZ M W, KIRSCH J, WILLIAMSON E E, et al. Utility of nongated multidetector computed tomography for detection of left atrial thrombus in patients undergoing catheter ablation of atrial fibrillation[J]. JACC Cardiovasc Imag, 2009, 2(1): 69-76.

    [37] [37] GOROG D A, BECKER R C. Point-of-care platelet function tests: relevance to arterial thrombosis and opportunities for improvement[J]. J Thromb Thrombolysis, 2021, 51(1): 1-11.

    Tools

    Get Citation

    Copy Citation Text

    ZHOU Zhenyu, ZHANG Qiqiang, JIA Congcong, DI Xuemei, YU Meixiang, CAO Yan, ZHANG Hai. Application advances of new methods for thrombus screening and rapid detection[J]. Journal of Tongji University(Medical Science), 2025, 46(3): 391

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 30, 2024

    Accepted: Aug. 26, 2025

    Published Online: Aug. 26, 2025

    The Author Email: ZHANG Hai (zhxdks2005@126.com)

    DOI:10.12289/j.issn.2097-4345.24313

    Topics