Acta Optica Sinica, Volume. 42, Issue 19, 1906002(2022)

Sensitivity Improvement of Plasmonic Optical Fiber Sensors with Graphene-Metal Nanowire Array

Lizhen Zeng1, Zetao Ou2, Hongyan Yang3, Yongfu Su3, Jiapeng Su2, Jiayu Chen2, and Gongli Xiao2、*
Author Affiliations
  • 1Graduate School, Guilin University of Electronic Technology, Guilin 541004, Guangxi , China
  • 2Guangxi Key Laboratory of Precision Navigation Technology and Application, Guilin University of Electronic Technology, Guilin 541004, Guangxi , China
  • 3School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, Guangxi , China
  • show less
    Figures & Tables(5)
    Schematic diagrams of D-type plasmonic optical fiber sensors. Its side is polished and coated with (a) gold film structure,(b) graphene-gold film-graphene structure, and (c) graphene-metal nanowire array structure; (d) three-dimensional structure diagram
    Plasmonic optical fiber sensor. (a) Resonance analysis of three models; (b) dispersion relation and mode analysis of gold film structure model
    Optimization of gold film thickness t and gold nanowire diameter d. (a) Relationship between t and loss for refractive indexes of 1.33 and 1.34, respectively; (b) influence of t on performance of sensor; (c) relationship between d and loss for refractive indexes of 1.33 and 1.34, respectively; (d) influence of d on performance of sensor
    Loss, refractive index, and resonance wavelength when RI to be measured is changing. (a)-(c) Change of transmission loss with wavelength; (d)-(f) change of resonance wavelength
    • Table 1. Performance comparison of various fiber optic sensors

      View table

      Table 1. Performance comparison of various fiber optic sensors

      ReferenceRI rangeSensitivity /(nm·RIU-1Average sensitivity /(nm·RIU-1Published year
      Ref.[41.3332-1.37103074.342019
      Ref.[111.3200-1.38007000.002020
      Ref.[381.3300-1.41006875.002020
      Ref.[391.3300-1.38007000.002021
      Ref.[401.3300-1.3700525.002021
      Ref.[411.3300-1.40003475.142021
      Ref.[421.3200-1.36006430.002014
      Ref.[431.3330-1.40406328.002019
      Ref.[441.3400-1.42004284.802021
      Our work1.3300-1.40007383.794136.00
    Tools

    Get Citation

    Copy Citation Text

    Lizhen Zeng, Zetao Ou, Hongyan Yang, Yongfu Su, Jiapeng Su, Jiayu Chen, Gongli Xiao. Sensitivity Improvement of Plasmonic Optical Fiber Sensors with Graphene-Metal Nanowire Array[J]. Acta Optica Sinica, 2022, 42(19): 1906002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Dec. 13, 2021

    Accepted: Apr. 1, 2022

    Published Online: Oct. 18, 2022

    The Author Email: Xiao Gongli (xgl.hy@126.com)

    DOI:10.3788/AOS202242.1906002

    Topics