Matter and Radiation at Extremes, Volume. 5, Issue 6, 064401(2020)
Region-of-interest micro-focus computed tomography based on an all-optical inverse Compton scattering source
Fig. 1. Schematic layout of experiment. The all-optical inverse Compton scattering source (AOCS) X-ray pulse (yellow) is generated by colliding a laser wakefield acceleration (LWFA) electron beam (blue) with the reflected laser pulse (red) using a plasma mirror. When x-ray photons hit the CsI(Tl) scintillation screen, visible light flashes (orange) are triggered and then captured by an electron-multiplying charge-coupled device.
Fig. 2. LWFA electron-beam characterization: (a) average spectrum of electron beams for 80 consecutive shots measured by an electron spectrometer based on a dipole magnet, where the blurred curve shows the FWHM error and the black dashed line shows the detection threshold; (b) average angular divergence of electron beams for 80 consecutive shots.
Fig. 3. AOCS characterization: (a) accumulated X-ray profile on detector for 50 consecutive shots; (b) X-ray intensity profile attenuated by multi-sector filter set (comprising seven aluminum plates of thickness 0.35 mm–8 mm and seven copper plates of thickness 0.35 mm–9 mm) for 50 consecutive shots; (c) on-axis X-ray spectrum deduced using the data in (b), where the blurred curve shows the error range and the inset shows the calculation error after each iteration. The single-shot source size (d) and the accumulated source size for 80 consecutive shots (e) are measured by the knife-edge technique, and the insets are the images of the sharp edge. (f) Accumulated projection image of a 10-lp/mm line pair for 80 consecutive shots and one of its line-outs, where a ∼20-
Fig. 4. AOCS-based region-of-interest (ROI) micro-focus computed tomography (CT) imaging: (a) illustration of test object, with the ROI highlighted by a red dashed circle; (b) 60-shot accumulated projection image; (c) curve of modulation transfer function of tube edge marked by a black dashed line in the projection image (b); (d) three-dimensional reconstructed image within the ROI; (e) one slice of the tomographic image in (d). The ROIs in (b) and (e) are highlighted by a red dashed rectangle and circle, respectively.
Fig. 5. Numerical simulation of AOCS-based ROI micro-focus CT for a turbine blade: (a) simulation layout—a turbine blade is placed in the x-ray path, with three sets of line pairs embedded in the ROI (within the red dashed circle); (b) photon energy and divergence distribution of AOCS (divergence within 5 mrad is used in the CT scanning); (c) reconstructed ROI of turbine blade; (d) line-outs of reconstructed line pairs with different noise levels (contrasts of the line pairs are labeled).
Get Citation
Copy Citation Text
Yue Ma, Jianfei Hua, Dexiang Liu, Yunxiao He, Tianliang Zhang, Jiucheng Chen, Fan Yang, Xiaonan Ning, Zhongshan Yang, Jie Zhang, Chih-Hao Pai, Yuqiu Gu, Wei Lu. Region-of-interest micro-focus computed tomography based on an all-optical inverse Compton scattering source[J]. Matter and Radiation at Extremes, 2020, 5(6): 064401
Category: Fundamental Physics At Extreme Light
Received: Jun. 1, 2020
Accepted: Sep. 8, 2020
Published Online: Nov. 24, 2020
The Author Email: