Chinese Journal of Lasers, Volume. 50, Issue 18, 1804004(2023)
Experimental Study of Forward Laser Time Transfer Based on Satellite Retroreflector
Fig. 8. Results of two-way FLTT with a common clock (BDS45: RMS of clock difference between 39800 and 40700 days seconds is 65 ps; BDS22: RMS of clock difference between 41000 and 41200 days seconds is 65 ps)
Fig. 9. Results of one-way FLTT with a common clock (BDS45: RMS of clock difference between 39800 and 40700 days seconds is 95 ps; BDS22: RMS of clock difference between 41000 and 41200 days seconds is 92 ps)
Fig. 10. Results of two-way FLTT with non-common clocks (BDS21: RMS of clock difference is 70 ps; Galileo206: RMS of clock difference is 62 ps)
Fig. 11. Results of one-way FLTT with non-common clocks (BDS21: RMS of clock difference is 96 ps; Galileo206: RMS of clock difference is 90 ps)
|
Get Citation
Copy Citation Text
Renfang Geng, Zhibo Wu, Yong Huang, Haisheng Lin, Rongzong Yu, Kai Tang, Haifeng Zhang, Zhongping Zhang. Experimental Study of Forward Laser Time Transfer Based on Satellite Retroreflector[J]. Chinese Journal of Lasers, 2023, 50(18): 1804004
Category: Measurement and metrology
Received: Jun. 13, 2022
Accepted: Nov. 23, 2022
Published Online: Aug. 28, 2023
The Author Email: Zhibo Wu (wzb@shao.ac.cn)