High Power Laser and Particle Beams, Volume. 35, Issue 2, 025001(2023)

Design of magnet power supply system for Quasi-Axisymmetric test of Chinese First Quasi-Axisymmetric Stellarator

Jian Xiong1, Hai Liu1、*, Weimin Xuan1,2, and Yuhong Xu1
Author Affiliations
  • 1Department of Physics, Southwest Jiaotong University, Chendu 610031, China
  • 2Southwest Institute of Physics of Nuclear Industry, Chengdu 610225, China
  • show less
    Figures & Tables(10)
    Distribution diagram of magnet coil of CFQS device
    Topologies of 12-pulse power supply system
    Output current ripple of equivalent 12 pulse power supply system
    Equivalent switching network
    Filter topology
    TFC power supply output current waveforms
    Load current ripple of each capacitance parameter
    Load current ripple under different temperature rise
    FFT analysis of network side current of power supply system
    • Table 1. Parameters of coils

      View table
      View in Article

      Table 1. Parameters of coils

      No.${R_{\rm{d}}}$/mΩ ${L_{\rm{d}}}$/mH ${I_{\rm{d}}}$/A
      MC1435.6782.52450
      MC2429.5081.12450
      MC3415.6278.74450
      MC4401.2375.97450
      TFC10228.133220
      TFC32210.002.7220
      TFC70173.572.16220
      OV230.5918.85450
      IV735450
    Tools

    Get Citation

    Copy Citation Text

    Jian Xiong, Hai Liu, Weimin Xuan, Yuhong Xu. Design of magnet power supply system for Quasi-Axisymmetric test of Chinese First Quasi-Axisymmetric Stellarator[J]. High Power Laser and Particle Beams, 2023, 35(2): 025001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Pulsed Power Technology

    Received: May. 20, 2022

    Accepted: Sep. 21, 2022

    Published Online: Feb. 16, 2023

    The Author Email: Liu Hai (liuhai@swjtu.edu.cn)

    DOI:10.11884/HPLPB202335.220164

    Topics