Acta Optica Sinica, Volume. 38, Issue 2, 0222001(2018)

Design of Hyperspectral Resolution Ultraviolet Offner Imaging Spectrometer System

Yuji Zhu1,2,3, Dayi Yin1,2,3、*, Yonghe Chen1,2, and Baichuan Ren1,2
Author Affiliations
  • 1 Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
  • 2 Key Laboratory of Infrared System Detection and Imaging Technology, Chinese Academy of Sciences, Shanghai 200083, China
  • 3 University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(12)
    Schematic diagram of Offner configuration
    Schematic diagram of spectral imaging system with convex grating based on Offner configuration
    Optical configuration diagram of (a) initial and (b) optimized Offner convex grating spectral imaging system
    Spot diagram of the initial configuration with the wavelength of (a) 0.25 μm, (b) 0.325 μm, (c) 0.4 μm; MTF curves of the initial configuration with the wavelength of (d) 0.25 μm, (e) 0.325 μm, (f) 0.4 μm
    Spot diagram of the optimized configuration with the wavelength of (a) 0.25 μm, (b) 0.325 μm, (c) 0.4 μm; MTF curves of the optimized configuration with the wavelength of (d) 0.25 μm, (e) 0.325 μm, (f) 0.4 μm
    (a) Maximum smile and (b) maximum keystone of the initial configuration at different wavelengths
    (a) Maximum smile and (b) maximum keystone of the optimized configuration at different wavelengths
    Encircled energy curves of the initial configuration at central and edge wavelengths. (a) Edge wavelength of 250 nm; (b) central wavelength of 325 nm; (c) edge wavelength of 400 nm
    Encircled energy curves of the optimized configuration at central and edge wavelengths. (a) Edge wavelength of 250 nm; (b) central wavelength of 325 nm; (c) edge wavelength of 400 nm
    • Table 1. Main design parameters of the system

      View table

      Table 1. Main design parameters of the system

      ParameterValue
      NA0.12
      Wavelength250~400 nm
      Spectral resolution0.3 nm
      Slit size40 mm×0.125 mm
      CCDPixel number: 106,pixel size: (13×13) μm
      MTF≥0.75
      Keystone & smileWithin 10% of the pixel size
    • Table 2. Optical structural parameters of the initial Offner convex grating spectral imaging system

      View table

      Table 2. Optical structural parameters of the initial Offner convex grating spectral imaging system

      SurfaceRadius /mmGlassSize /mmThickness /mmLines /(lp/mm)
      1-720.0MirrorФ200-363.143-
      Stop-356.857GratingФ90339.546243
      3-696.402MirrorФ200-696.401-
      ImageInfinity----
    • Table 2. Structural parameters of the optimized Offner convex grating spectral imaging system

      View table

      Table 2. Structural parameters of the optimized Offner convex grating spectral imaging system

      SurfaceRadius /mmGlassSize /mmThickness /mmLines /(lp/mm)
      1-110.5Fused silicaФ8015-
      2-125.8--179.1-
      3-303.7MirrorФ130-159.2-
      Stop-144.5GratingФ20159.2600
      5-303.7MirrorФ130-179.1-
      6-125.8Fused silicaФ80-15-
      7-110.5---109.8-
      ImageInfinity----
    Tools

    Get Citation

    Copy Citation Text

    Yuji Zhu, Dayi Yin, Yonghe Chen, Baichuan Ren. Design of Hyperspectral Resolution Ultraviolet Offner Imaging Spectrometer System[J]. Acta Optica Sinica, 2018, 38(2): 0222001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Aug. 17, 2017

    Accepted: --

    Published Online: Aug. 30, 2018

    The Author Email: Yin Dayi (yindayi@mail.sit)

    DOI:10.3788/AOS201838.0222001

    Topics