Chinese Journal of Lasers, Volume. 46, Issue 10, 1010003(2019)

Online Monitoring and Controlling Technique of Loop Gain of Fiber Optic Current Sensors

Jia Yu1、*, Xiaxiao Wang1, Chunxi Zhang1, Chuansheng Li2, and Fu Ma1
Author Affiliations
  • 1School of Instrument Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China
  • 2National Institute of Metrology, Beijing 100029, China
  • show less
    Figures & Tables(11)
    Configuration of FOCS
    Digital control system of FOCS
    Simplified discrete dynamic model of FOCS
    Loop gain versus frequency characteristic. (a) Loop gain versus amplitude; (b) loop gain versus phase
    Scheme of loop gain online monitoring
    Sketch map of output demodulation of FOCS
    Measurement accuracy versus loop gain. (a) Scale factor error versus loop gain; (b) phase error versus loop gain
    Stable controlling technique for loop gain
    Measurement accuracy versus amplification. (a) Loop gain versus preamplifier gain; (b) scale factor error versus preamplifier gain;(c) phase error versus preamplifier gain
    • Table 1. Amplification versus scale factor error and phase error

      View table

      Table 1. Amplification versus scale factor error and phase error

      R /kΩAmplificationLoop gainScale factor error /%Phase error /(')
      11.810025.391500.1743000.000954-0.30811
      10.230021.994500.150200-0.017320-1.46754
      8.870019.070500.131200-0.015710-3.34291
      7.880016.942000.115400-0.018120-4.60070
      6.750014.512500.099210-0.013910-7.24607
      5.840012.556000.085590-0.014540-9.95570
      5.060010.879000.074250-0.010760-13.09000
      4.02008.643000.059020-0.015130-19.65430
      3.63007.804500.053370-0.021500-23.11220
      2.47005.310500.036280-0.023450-35.33240
      1.70803.672200.025320-0.031410-59.21930
      1.00702.165050.014780-0.074800-113.21600
      0.62701.348050.009220-0.193810-192.63300
      0.11320.243380.001671-5.736640-1150.83000
    • Table 2. Preamplifier gain and loop gain versus scale factor error and phase error with stable controlling technique

      View table

      Table 2. Preamplifier gain and loop gain versus scale factor error and phase error with stable controlling technique

      R /kΩAmplificationLoop gainPhase error /(')Scale factor error /%
      12.03025.864500.17750.28430.00600
      11.06023.779000.17700.1745-0.01600
      10.04021.586000.1772-0.2352-0.00850
      8.99019.328500.1777-0.36520.02800
      8.05017.307500.1777-0.2635-0.00700
      7.01015.071500.17730.7851-0.01150
      5.98012.857000.17710.4937-0.02800
      5.05010.857500.17750.58160.07565
      4.0208.643000.17740.28740.01225
      3.0406.536000.1772-0.32560.01725
      2.1504.622500.1771-0.1571-0.02055
      1.0702.300500.1773-0.6143-0.03840
      0.5451.171750.1768-1.5234-0.04570
      0.1640.352600.1765-1.0781-0.04270
    Tools

    Get Citation

    Copy Citation Text

    Jia Yu, Xiaxiao Wang, Chunxi Zhang, Chuansheng Li, Fu Ma. Online Monitoring and Controlling Technique of Loop Gain of Fiber Optic Current Sensors[J]. Chinese Journal of Lasers, 2019, 46(10): 1010003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: remote sensing and sensor

    Received: Apr. 22, 2019

    Accepted: Jun. 10, 2019

    Published Online: Oct. 25, 2019

    The Author Email: Yu Jia (yu_jia1985@126.com)

    DOI:10.3788/CJL201946.1010003

    Topics