Matter and Radiation at Extremes, Volume. 8, Issue 3, 036901(2023)

Estimation of plasma parameters of X-pinch with time-resolved x-ray spectroscopy

Seunggi Ham1, Jonghyeon Ryu1, Hakmin Lee1, Sungbin Park1, Y.-C. Ghim2, Y. S. Hwang1, and Kyoung-Jae Chung1、a)
Author Affiliations
  • 1Department of Energy Systems Engineering, Seoul National University, Seoul 08826, South Korea
  • 2Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, South Korea
  • show less
    Figures & Tables(22)
    Response curves of the filtered AXUV diode array. The positions of the channel numbers indicate the spectral edges of each channel. Reproduced with permission from Ham et al., Rev. Sci. Instrum. 92(5), 053509 (2021). Copyright 2021 AIP Publishing.
    SNU X-pinch with the filtered AXUV diode array. The filtered AXUV diode array is mounted with half on each of the opposite vacuum ports. The distance between the wire load and AXUV diodes is 765 mm. Reproduced with permission from Ham et al., Rev. Sci. Instrum. 92(5), 053509 (2021). Copyright 2021 AIP Publishing.
    Currents measured by short circuit test. Black and red lines show the currents generated with charging voltages of 50 and 55 kV, respectively.
    (a) Typical x-ray signals of Cu wire X-pinches with charging voltages of 50 kV. The yellow areas indicate ranges of three bursts of x-rays. (b)–(d) Signals of the first, second, and third bursts, respectively, on narrower time scales.
    (a) Typical x-ray signals of Cu wire X-pinches with charging voltages of 55 kV. The yellow areas indicate the ranges of three bursts of x-rays. (b)–(d) Signals of the first, second, and third bursts, respectively, on narrower time scales.
    Synthetic spectra of Cu plasma with electron temperatures of 0.1 (black), 0.8 (red), and 1.5 (blue) keV. The electron density is 1021 cm−3.
    Synthetic spectra of Cu plasmas with electron densities of 1021 (black) and 1023 (red) cm−3. The electron temperature is 0.8 keV.
    Reconstructed (dotted) and synthetic (solid) spectra with different plasma parameters: (a) electron density 1023 cm−3, electron temperature 1.0 keV, and fast electron fraction 20%; (b) electron density 1022 cm−3, electron temperature 1.5 keV, and fast electron fraction 0%.
    X-ray power ratios with different electron temperatures and electron densities obtained from the FLYCHK code: (a) first ratio r1; (b) second ratio r2.
    Synthetic spectra with different characteristic energies of 10 (black), 20 (red), and 30 (blue) keV. The electron temperature and density are 1.6 keV and 1023 cm−3, respectively, which are similar to those of an HS. The fast electron fraction is 9%.
    Synthetic spectra with different characteristic energies of 10 (black), 20 (red), and 30 (blue) keV. The electron temperature and density are 0.1 keV and 1023 cm−3, respectively, which correspond to a low-temperature plasma. The fast electron fraction is 9%.
    Synthetic spectra with fast electron fractions of 0% (black) and 5% (red). The electron temperature is 0.8 keV and the electron density is 1021 cm−3.
    X-ray power ratios with fast electron fractions of 1% [(a) and (b)], 5% [(c) and (d)], and 15% [(e) and (f)].
    Synthetic spectra calculated with various plasma sizes: optically thin (black), 1 µm (red), 10 µm (blue), 100 µm (orange) and 1 mm (green). (a)–(d) Spectra without fast electrons: (a) and (b) spectra with electron temperature 0.8 keV and electron densities 1021 and 1023 cm−3, respectively; (c) and (d) spectra with electron temperature 1.5 keV and electron densities 1021 and 1023 cm−3, respectively. (e) and (d) Spectra with fast electron fraction 5%, electron temperature 0.8 keV, and electron densities of 1021 and 1023 cm−3, respectively.
    Example of a comparison of the x-ray power ratios from the first peak of the 50 kV case. (a) and (b) Plasma parameters of the first and second ratios, respectively, with errors less than 10%. (c) Plasma parameters with averaged errors of the x-ray power ratios less than 10%.
    Signals of channels 1, 2, and 10 and temporal evolution of estimated electron densities, electron temperatures, and fast electron fractions for the first burst of the 50 kV case. Estimated plasma parameters of three x-ray peaks from peak-integrated x-ray powers are plotted together.
    Signals of channels 1, 2, and 10 and temporal evolution of estimated electron densities, electron temperatures, and fast electron fractions for the first burst of the 55 kV case. Estimated plasma parameters of two x-ray peaks from peak-integrated x-ray powers are plotted together.
    Signals of channels 1, 2, and 10 and temporal evolution of estimated electron densities, electron temperatures, and fast electron fractions for the second burst of the 50 kV case.
    Signals of channels 1, 2, and 10 and temporal evolution of estimated electron densities, electron temperatures, and fast electron fractions for the second burst of the 55 kV case.
    Signals of channels 1, 2, and 10 and temporal evolution of estimated electron densities, electron temperatures, and fast electron fractions for the third burst of the 50 kV case.
    Signals of channels 1, 2, and 10 and temporal evolution of estimated electron densities, electron temperatures, and fast electron fractions for the third burst of the 55 kV case.
    • Table 1. Filter materials and their thicknesses: (a) low-energy channels combined with beryllium filters with a thickness of 10 µm; (b) high-energy channels for x-ray energies above 2 keV. Reproduced with permission from Ham et al., Rev. Sci. Instrum. 92(5), 053509 (2021). Copyright 2021 AIP Publishing.

      View table
      View in Article

      Table 1. Filter materials and their thicknesses: (a) low-energy channels combined with beryllium filters with a thickness of 10 µm; (b) high-energy channels for x-ray energies above 2 keV. Reproduced with permission from Ham et al., Rev. Sci. Instrum. 92(5), 053509 (2021). Copyright 2021 AIP Publishing.

      (a) CH12345
      FilterTeflonAlZrPdSn
      Thickness (μm)610.50.41
      (b) CH678910
      FilterTiCrFeNiZn
      Thickness (μm)1058912
    Tools

    Get Citation

    Copy Citation Text

    Seunggi Ham, Jonghyeon Ryu, Hakmin Lee, Sungbin Park, Y.-C. Ghim, Y. S. Hwang, Kyoung-Jae Chung. Estimation of plasma parameters of X-pinch with time-resolved x-ray spectroscopy[J]. Matter and Radiation at Extremes, 2023, 8(3): 036901

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Radiation and Hydrodynamics

    Received: Oct. 20, 2022

    Accepted: Feb. 20, 2023

    Published Online: Jun. 30, 2023

    The Author Email: Kyoung-Jae Chung (jkjlsh1@snu.ac.kr)

    DOI:10.1063/5.0131369

    Topics