Chinese Journal of Lasers, Volume. 42, Issue 5, 508003(2015)

Research of Peak Count Rate Scanning Method for Single Photon Detector Used in High Precision Optical Transfer Time Measurement

Zeng Zhilong*, Zhu Yong, Lu Lin, Zhang Baofu, Wu Chuanxin, and Wei Yimei
Author Affiliations
  • [in Chinese]
  • show less
    References(9)

    [1] [1] Guo-Liang Shentu, Qi-Chao Sun, Xiao Jiang, et al.. 217 km long distance photon-counting optical time-domain reflectometry based on ultra-low noise up-conversion single photon detector[J]. Opt Express, 2013, 21(21): 24674-24679.

    [2] [2] Prochazka I, Blazej J, Kodet J. New technologies for time transfer with picoseconds precision and accuracy[C]. Frequency Control Symposium (FCS), 2012 IEEE International, 2012: 1-7.

    [3] [3] Ribordy G, Gautier J D, Zbinden H, et al.. Performance of InGaAs/InP avalanche photodiodes as gated-mode photon counters[J]. Appl Opt, 1998, 37(12): 2272-2277.

    [4] [4] Huang Jianhua, Wu Guang, Zeng Heping. Study of 1.5 GHz harmonics ultrashort pulse gated InGaAs/InP avalanche photodiode single-photon detection[J]. Acta Optica Sinica, 2014, 34(2): 0204001.

    [5] [5] Thew R T, Curtz N, Eraerds P, et al.. Approaches to single photon detection[J]. Nuclear Instrum Meth Phys Research A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009, 610(1): 16-19.

    [7] [7] Li Xiongjie, Ding Jingxin, Tang Ruikai, et al.. Research on quantum statistic properties of photon number in pulse mode nonlinear frequency up-conversion[J]. Acta Optica Sinica, 2014, 34(5): 0527002.

    CLP Journals

    [1] Zhu Bo, Zhu Yong, Lu Lin, Zhang Baofu, Wu Chuanxin, Wei Yimei. Measurement Meathod for Real-Time Transmission of Optical Singal Based on Single Photon Detection[J]. Chinese Journal of Lasers, 2016, 43(2): 205003

    [2] Xiang Jinsong, Wang Ju, Wu Tao, Zhang Xuewang. Data Recovery Technique for Asynchronous Sampling Signal Modulated by Optical Pulse Position Based on Pulse Broadening Waveform[J]. Acta Optica Sinica, 2017, 37(1): 106004

    Tools

    Get Citation

    Copy Citation Text

    Zeng Zhilong, Zhu Yong, Lu Lin, Zhang Baofu, Wu Chuanxin, Wei Yimei. Research of Peak Count Rate Scanning Method for Single Photon Detector Used in High Precision Optical Transfer Time Measurement[J]. Chinese Journal of Lasers, 2015, 42(5): 508003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Nov. 10, 2014

    Accepted: --

    Published Online: Apr. 8, 2015

    The Author Email: Zhilong Zeng (zzllinyun@163.com)

    DOI:10.3788/cjl201542.0508003

    Topics