Chinese Journal of Quantum Electronics, Volume. 42, Issue 2, 177(2025)
Optimized design and error analysis of vibration sensitivity of horizontally placed cylindrical reference cavity
Ultra-narrow linewidth frequency-stabilized lasers play a crucial role in the fields of precision measurement, precision spectroscopy, atomic frequency standard and other fields, and its frequency stability depends on the performance of the reference ultra-stable cavity. The horizontally placed ultra-stable cavity is highly sensitive to external vibrations. Usually, there is a magnitude difference between actual vibration sensitivity and its theoretical design, which makes vibration noise an important factor limiting the stability of the ultra-stable cavity. This paper takes a cylindrical horizontal cavity as an example and proposes a cavity design with a low vibration-sensitive of 7.3×
Get Citation
Copy Citation Text
Yanmei HAO, Yao HUANG, Baolin ZHANG, Qunfeng CHEN, Hua GUAN, Kelin GAO. Optimized design and error analysis of vibration sensitivity of horizontally placed cylindrical reference cavity[J]. Chinese Journal of Quantum Electronics, 2025, 42(2): 177
Category:
Received: Sep. 1, 2023
Accepted: --
Published Online: Apr. 1, 2025
The Author Email: Qunfeng CHEN (qfchen@wipm.ac.cn), Hua GUAN (guanhua@wipm.ac.cn)