Chinese Journal of Lasers, Volume. 37, Issue 3, 826(2010)

A Corneal Topography Based on Hartmann-Shack Sensor

Yang Jinsheng1,2,3、*, Rao Xuejun1,2, and Rao Changhui1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(10)

    [1] [1] P. Artal,A. Guirao,E. Berrio et al.. Compensation of corneal aberrations by the internal optics in the human eye[J]. J. Math. Imaging Vision,2001,1:1-8

    [2] [2] Yobani Mejía-Barbosa,Daniel Malacara-Hernández. A review of methods for measuring corneal topography[J]. Optometry and Vision Science,2001,78(4):240-253

    [6] [6] Ling Ning,Zhang Yudong,Rao Xuejun et al.. Measurement and correction in time of high order aberrations[C]. Optics and Optical Engineering-Prcoessing of Congratulation for Wang Daheng Academician′s 90 Birthday,Beijing:Science Press,2005. 73-89

    [8] [8] Liang Junzhong,Bernhard Grimm,Stefan Goelz et al.. Objective measurement of wave aberrations of the human eye with the use of Hartmann-Shack wave-front sensor[J]. J. Opt. Soc. Am. A,1994,11(7):1949-1957

    [9] [9] Fan Zhou,Xin Hong,Donald T. Miller et al.. Validation of a combined corneal topographer and aberrometer based on Shack-Hartmann wave-front sensing[J]. J. Opt. Soc. Am. A.,2004,21(5):683-696

    [10] [10] Daniel R. Neal,James Copland,David Neal. Shack-Hartmann wavefront sensor precision and accuracy[C]. SPIE,2002,4779:148-160

    CLP Journals

    [1] Zhao Qi, Jiang Zewei, He Yong, Lu Feng. Development and Calibration of a Radial-Shearing Interferometer[J]. Laser & Optoelectronics Progress, 2012, 49(4): 41204

    [2] Wang Shaobai, Wang Chunhong, Rao Changhui. Centroid Detection Error Analysis of a Point Source with a Single Blind Pixel in Spot Area[J]. Laser & Optoelectronics Progress, 2012, 49(3): 30101

    [3] Liu Yongji, Wang Yan, Wang Zhaoqi, Zuo Tong, Kong Qiang. Study on the Measurement Error on Corneal Vergence for Eyes After Corneal Refractive Surgery[J]. Chinese Journal of Lasers, 2011, 38(s1): 104003

    [4] Sui Chenghua, Wo Shengjie, Gao Nan, Xu Danyang, Han Yonghao, Du Chunnian. Design and Implementation of Imaging System for Corneal Topography Based on Placido Disk[J]. Acta Optica Sinica, 2016, 36(12): 1222001

    [5] Chen Zhijie, Li Dahai, Zhang Chen, Song Yuwei, Xu Wenfeng, Huang Yi. Study of Anterior Corneal Surface Design Based on Reverse Ray-Tracing Method[J]. Laser & Optoelectronics Progress, 2015, 52(6): 62204

    Tools

    Get Citation

    Copy Citation Text

    Yang Jinsheng, Rao Xuejun, Rao Changhui. A Corneal Topography Based on Hartmann-Shack Sensor[J]. Chinese Journal of Lasers, 2010, 37(3): 826

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: measurement and metrology

    Received: Apr. 17, 2009

    Accepted: --

    Published Online: Mar. 11, 2010

    The Author Email: Jinsheng Yang (jinsyang@163.com)

    DOI:10.3788/cjl20103703.0826

    Topics