Chinese Optics Letters, Volume. 13, Issue 9, 093401(2015)

Application of polycapillary x ray lens to eliminate both the effect of x ray source size and scatter of the sample in laboratory tomography

Xuepeng Sun1,2,3, Zhiguo Liu1,2,3, Tianxi Sun1,2,3、*, Longtao Yi1,2,3, Weiyuan Sun1,2,3, Fangzuo Li1,2,3, Bowen Jiang1,2,3, Yongzhong Ma4, and Xunliang Ding1,2,3
Author Affiliations
  • 1The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875, China
  • 2College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875, China
  • 3Beijing Radiation Center, Beijing 100875, China
  • 4Center for Disease Control and Prevention of Beijing, Beijing 100013, China
  • show less
    Figures & Tables(13)
    Scheme of the x ray absorption imaging device based on a polycapillary x ray lens.
    (a) Picture of the PPXRL. (b) Picture of the PCXRL. (c) Cross section of the outside of the PPXRL. The channel size is about 7 μm.
    Image of output beam of PPXRL at the distance of 30 cm from the CCD detector.
    X ray intensity distribution of the output beam of the PPXRL at a distance of 30 cm from the CCD detector.
    Distribution of the gain of the PPXRL at a distance of 30 cm from the CCD detector.
    Picture of the mesh used in the experiment.
    Image of the mesh at a distance of 20 cm from the PPXRL taken by the tomography device (a) with and (b) without the PCXRL.
    Corresponding intensity profiles of the images in Fig. 7(a) and 7(b).
    (a) Ratio of intensities in Fig. 8. (b) Image of Fig. 7 after flat-field correction.
    Image of the mesh in different places. (a) L1=20 cm and L2=2 cm. (b) L1=20 cm and L3=2 cm.
    Contrast of the images as a function of the distance between the detector and the outside of PCXRL (the red line), and between the sample and the inside of PCXRL (the black line).
    Distribution of the local angular divergence of the output beam from the PPXRL.
    • Table 1. The Main Geometric Parameters of the PPXRL and PCXRL

      View table
      View in Article

      Table 1. The Main Geometric Parameters of the PPXRL and PCXRL

      ParameterPPXRLPCXRL
      Length/mm73.243.7
      Input Diameter/mm3.74.3
      Output Diameter/mm4.34.3
      Input Focal Distance/mm71.2Not available
      Number of the Capillary/ca320000320000
    Tools

    Get Citation

    Copy Citation Text

    Xuepeng Sun, Zhiguo Liu, Tianxi Sun, Longtao Yi, Weiyuan Sun, Fangzuo Li, Bowen Jiang, Yongzhong Ma, Xunliang Ding, "Application of polycapillary x ray lens to eliminate both the effect of x ray source size and scatter of the sample in laboratory tomography," Chin. Opt. Lett. 13, 093401 (2015)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: X-ray Optics

    Received: Apr. 11, 2015

    Accepted: Jul. 9, 2015

    Published Online: Sep. 14, 2018

    The Author Email: Tianxi Sun (stx@bnu.edu.cn)

    DOI:10.3788/COL201513.093401

    Topics