Acta Optica Sinica, Volume. 23, Issue 5, 609(2003)

Sensitive Detection of CO2 Molecule Using Near Infrared Diode Laser Absorption Spectroscopy

[in Chinese]*, [in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    References(7)

    [1] [1] Reid J, Garside B K, Shewchun J et al.. High sensitivity point monitoring of atmospheric gases employing tunable diode laser. Appl. Opt., 1978, 17(11):1806~1810

    [2] [2] Bomse D. Diode lasers finding trace gases in the lab and the plant. Photonics Spectra, 1995, (6):88~94

    [3] [3] Cooper D E, Martinelli R U. Near-infrared diode lasers monitor molecular species. Laser Focus World, 1992, (11):133~137

    [4] [4] Schiff H I, Chanda A, Pisano J et al.. The LasIR-a tunable diode laser system for environmental and industrial application. Proc. SPIE, 1999, 3535:132~140

    [5] [5] Cassidy D T, Bonnell L J. Trace gas detection with short-exteral-cavity InGaAsP diode laser transmitter modules operating at 1.58 μm. Appl. Opt., 1998, 27(13):2688

    [6] [6] Sonnenfroh D M, Allen M G. Observation of CO and CO2 absorption near 1.57 μm with an external-cavity diode laser. Appl. Opt., 1997, 36(15):3298

    [7] [7] Werle P. A review of recent advances in semiconductor laser based gas monitors. Spectrochimica Acta Part A, 1998, 54(2):197~236

    CLP Journals

    [1] Zhang Shuai, Liu Wenqing, Zhang Yujun, Shu Xiaowen, Kan Ruifeng, He Ying, Geng Hui, Xu Zhenyu, Liu Jianguo. Application of Digital Filtering to the Gas Monitoring with TDLAS[J]. Acta Optica Sinica, 2010, 30(5): 1362

    [2] Zhao Jianhua, Zhao Chongwen, Wei Zhoujun, Gao Mingliang. Study on Monitoring Multi-Component Toxic Gases Based on Near-Infrared Spectroscopic Method[J]. Acta Optica Sinica, 2010, 30(2): 567

    [3] Yongquan Xiong, Bin Zhou, Yihong Wang, Hao Wang, Bubin Wang, Heyao Cheng, Shimin Wang. Calibration-Free One-Line Method Based on WavelengthModulation Spectroscopy[J]. Acta Optica Sinica, 2017, 37(9): 0930002

    [4] Wang Zhuo, Cao Jianian, Zhang Keke, Feng Linlin. Research on Practicality of Methane Gas Sensor Based on Harmonic Peak to Average Power Ratio[J]. Chinese Journal of Lasers, 2010, 37(6): 1505

    [5] Chen Jiuying, Liu Jianguo, He Yabo, Xu Zhenyu, Li Han, Yao Lu, Yuan Song, Ruan Jun, He Junfeng, Kan Ruifeng. Temperature Measurement of CO2 by Use of a Distributed-Feedback Diode Laser Sensor Near 2.0 μm[J]. Chinese Journal of Lasers, 2012, 39(11): 1108004

    [6] Jia Liangquan, Liu Wenqing, Liu Jianguo, Kan Ruifeng, Yao Lu, Xu Zhenyu, Dai Yunhai, Yuan Song, Wei Min, Zhang Guangle. Effects of Temperature and Pressure Changes on the Second Harmonic Inversion Results[J]. Chinese Journal of Lasers, 2014, 41(12): 1215004

    [7] HUANG Wei, GAO Xiao-ming, ZHANG Wei-jun, PEI Shi-xin, QU Jun, SHAO Jie, LI Xiao-yun, YANG Yong, LEI Li-qiao. Study of Near-Infrared Tunable Diode Laser Spectrometer[J]. Chinese Journal of Lasers, 2004, 31(s1): 263

    [8] Wang Lei, Tan Tu, Wang Guishi, Gao Xiaoming. Natural Gas Pipeline Leak Detection System for Laser Remote Sensing and Calibration[J]. Chinese Journal of Lasers, 2010, 37(11): 2912

    [9] Wang Guishi, Cai Tingdong, Wang Lei, Tan Tu, Zhang Weijun, Gao Xiaoming. Application of Digital Frequency Locking Techniques in Real-Time Measurement of Methane in Atmosphere[J]. Chinese Journal of Lasers, 2011, 38(10): 1008002

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Sensitive Detection of CO2 Molecule Using Near Infrared Diode Laser Absorption Spectroscopy[J]. Acta Optica Sinica, 2003, 23(5): 609

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Mar. 29, 2002

    Accepted: --

    Published Online: Jun. 27, 2006

    The Author Email: (xmgao@aiofm.ac.cn)

    DOI:

    Topics