Chinese Optics, Volume. 15, Issue 4, 825(2022)
Spectral irradiance degradation model of halogen tungsten lamps at wavelength from 400 nm to 1300 nm
[1] LU N M, DING L, ZHENG X B, et al. Introduction of the radiometric benchmark satellite being developed in China for remote sensing[J]. Journal of Remote Sensing, 24, 672-680.(Chinese)(2020).
[2] [2] YOON H W, GIBSON C E. NIST measurement services: spectral irradiance calibrations[R]. Gaithersburg: Optical Technology Division, Physical Measurement Labaty, National Institute of Stards Technology, 2011.
[3] ESPOSITO J A, XIONG X X, WU A SH, et al. MODIS reflective solar bands uncertainty analysis[J]. Proceedings of SPIE, 5542, 448-458(2004).
[4] KANG G, COSTE P, YOUN H, et al. An in-orbit radiometric calibration method of the geostationary ocean color imager[J]. IEEE Transactions on Geoscience and Remote Sensing, 48, 4322-4328(2010).
[5] BAUDIN G, MATTHEWS S, BESSUDO R, et al. Medium-resolution imaging spectrometer (MERIS) calibration sequence[J]. Proceedings of SPIE, 2819, 141-150(1996).
[6] CAO CH Y, XIONG J, BLONSKI S, et al. Suomi NPP VIIRS sensor data record verification, validation, and long-term performance monitoring[J]. Journal of Geophysical Research, 118, 11664-11678(2013).
[7] CZAPLA-MYERS J, ANDERSON N, THOME K, et al. The absolute radiometric calibration of the Landsat 8 Operational Land Imager using the reflectance-based approach and the Radiometric Calibration Test Site (RadCaTS)[J]. Proceedings of SPIE, 9218, 921819(2014).
[8] HUANG L K, CEBULA R P, HILSENRATH E. New procedure for interpolating NIST FEL lamp irradiances[J]. Metrologia, 35, 381-386(1998).
[9] SHAO X, CAO CH Y, LIU T C. Spectral dependent degradation of the solar diffuser on Suomi-NPP VIIRS due to surface roughness-induced Rayleigh scattering[J]. Remote Sensing, 8, 254(2016).
[10] OJANEN M, KÄRHÄ P, IKONEN E. Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range[J]. Applied Optics, 49, 880-886(2010).
[11] FU L, LEUTZ R, RIES H. Physical modeling of filament light sources[J]. Journal of Applied Physics, 100, 103528(2006).
[12] [12] FU L. Increasing the brightness of light sources[D]. Marburg: PhilippsUniversitat Marburg, 2006.
[13] LELAND J E, ARECCHI A V. Phase 2 analysis of Spectralon material for use in on-board calibration systems for the medium-resolution imaging spectrometer (MERIS)[J]. Proceedings of SPIE, 2475, 384-392(1995).
[14] [14] BERK A, ERSON G P, AYA P K, et al. . Modtran4 User’s Manual[M]. Hanscom AFB: Air Fce Research Labaty, 1999.
[15] [15] Technical Guide: reflectance materials coatings[R]. Labsphere, 1997.
Get Citation
Copy Citation Text
Ya-chao ZHANG, Xin YE, Zhi-wei XIA, Long SUI, Wei FANG. Spectral irradiance degradation model of halogen tungsten lamps at wavelength from 400 nm to 1300 nm[J]. Chinese Optics, 2022, 15(4): 825
Category: Original Article
Received: Nov. 30, 2021
Accepted: Feb. 22, 2022
Published Online: Sep. 6, 2022
The Author Email: Xin YE (yexin@ciomp.ac.cn)